Removal of Arsenic from Drinking Water by Batch and Continuous Electrocoagulation Processes Using Hybrid Al-Fe Plate Electrodes
| dc.contributor.author | Kobya, M. | |
| dc.contributor.author | Akyol, A. | |
| dc.contributor.author | Demirbas, E. | |
| dc.contributor.author | Oncel, M. S. | |
| dc.date.accessioned | 2025-10-29T11:34:13Z | |
| dc.date.issued | 2014 | |
| dc.department | Fakülteler, Temel Bilimler Fakültesi, Kimya Bölümü | |
| dc.description.abstract | Removals of arsenic from drinking water by electrocoagulation (EC) process using six different combinations of hybrid electrodes (Al-Fe), and Al-Al or Fe-Fe electrodes as all anodes and cathodes in a batch mode were evaluated. The removal process with monopolar series mode at optimum operating conditions (2.50 A/m(2), 150 mu g/L, and pH 7.0) indicated that Fe-Al-Al-Fe (anode-cathode-anode-cathode) hybrid plate electrode pairs were the most efficient choice in terms of arsenic removal efficiency (96% in 1 min) and operating cost (0.00202 Euro/m(3)). The arsenic removal from drinking water by continuous EC (CEC) process using Fe-Al-Al-Fe hybrid plate electrode pairs was also studied with respect to flow rates and initial arsenic concentrations. The effluent arsenic concentration of 10 mu g/L in the CEC process was achieved at 3 min for 0.05 L/min (5.9 mu g/L), 8 min for 0.10 L/min (6.3 mu g/L), and 20 min for 0.20 L/min (8.4 mu g/L), respectively. Amounts of the sludge and operating costs in the CEC process with respect to some experimental parameters such as operating time (3-20 min) and flow rate (0.05-0.20 L/min) at 150 mu g/L were determined as 0.0095-0.025 kg/m(3) and 0.009-0.060 Euro/m(3). (c) 2013 American Institute of Chemical Engineers Environ Prog, 33: 131-140, 2014 | |
| dc.identifier.doi | 10.1002/ep.11765 | |
| dc.identifier.endpage | 140 | |
| dc.identifier.issn | 1944-7442 | |
| dc.identifier.issn | 1944-7450 | |
| dc.identifier.issue | 1 | |
| dc.identifier.orcid | 0000-0001-6732-8893 | |
| dc.identifier.orcid | 0000-0001-5052-7220 | |
| dc.identifier.scopus | 2-s2.0-84891825839 | |
| dc.identifier.scopusquality | Q2 | |
| dc.identifier.startpage | 131 | |
| dc.identifier.uri | https://doi.org/10.1002/ep.11765 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14854/12771 | |
| dc.identifier.volume | 33 | |
| dc.identifier.wos | WOS:000329309300014 | |
| dc.identifier.wosquality | Q2 | |
| dc.indekslendigikaynak | Web of Science | |
| dc.indekslendigikaynak | Scopus | |
| dc.language.iso | en | |
| dc.publisher | Wiley | |
| dc.relation.ispartof | Environmental Progress & Sustainable Energy | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.snmz | KA_WOS_20251020 | |
| dc.subject | arsenic removal | |
| dc.subject | drinking water | |
| dc.subject | electrocoagulation | |
| dc.subject | hybrid Al-Fe plate electrodes | |
| dc.title | Removal of Arsenic from Drinking Water by Batch and Continuous Electrocoagulation Processes Using Hybrid Al-Fe Plate Electrodes | |
| dc.type | Article |