Modulus of Elasticity and Mechanical Properties Assessment of Historical Masonry Elements After Elevated Temperature: Experimental Study and Numerical Analysis

dc.contributor.authorKara, Ahmet Fazil
dc.contributor.authorÇakır, Ferit
dc.contributor.authorCalis, Metehan
dc.date.accessioned2025-10-29T11:09:01Z
dc.date.issued2025
dc.departmentFakülteler, Mühendislik Fakültesi, İnşaat Bölümü
dc.description.abstractHistorical masonry structures deteriorate over time, requiring restoration and strengthening. Hydraulic lime-based mortars (HLMs), due to their compatibility with historical materials, are commonly used for this purpose. This study examines the fire resistance of masonry walls constructed with HLMs. Masonry prisms with clay bricks were prepared using HLMs in accordance with material testing standards. Specimens were subjected to high temperatures ranging from 200 degrees C to 800 degrees C, followed by flexural-compression tests for mortar and compression tests for masonry prisms. A total of 20 masonry prism specimens, 15 brick specimens, and 15 mortar specimens were tested, including reference specimens at room temperature. Experimental results indicate that masonry prisms, clay bricks, and HLMs progressively lose their mechanical properties as temperature increases. The elastic modulus of masonry prisms was evaluated according to relevant standards, and Finite Element Analysis (FEA) was conducted to validate temperature-dependent material properties. The stress-strain response of M15 HLM masonry prisms was determined, addressing the absence of such data in EN 1996-1-2. Additionally, compression test results were compared with digital image correlation (DIC) analyses to enhance measurement accuracy. This study provides critical insights into the thermal performance of masonry walls with HLMs, contributing to the development of fire-resistant restoration materials.
dc.identifier.doi10.3390/buildings15132324
dc.identifier.issn2075-5309
dc.identifier.issue13
dc.identifier.orcid0000-0003-1169-6413
dc.identifier.scopus2-s2.0-105010272045
dc.identifier.scopusqualityQ1
dc.identifier.urihttps://doi.org/10.3390/buildings15132324
dc.identifier.urihttps://hdl.handle.net/20.500.14854/5628
dc.identifier.volume15
dc.identifier.wosWOS:001526460900001
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherMdpi
dc.relation.ispartofBuildings
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WOS_20251020
dc.subjectelastic modulus
dc.subjectmechanical properties
dc.subjectmasonry walls
dc.subjectelevated temperature
dc.subjecttransient thermal analysis
dc.subjectdigital image correlation
dc.titleModulus of Elasticity and Mechanical Properties Assessment of Historical Masonry Elements After Elevated Temperature: Experimental Study and Numerical Analysis
dc.typeArticle

Dosyalar