Amperometric Phenol Biosensor Based on Horseradish Peroxidase Entrapped PVF and PPy Composite Film Coated GC Electrode

dc.contributor.authorSulak, Meral Topcu
dc.contributor.authorErhan, Elif
dc.contributor.authorKeskinler, Buelent
dc.date.accessioned2025-10-29T11:30:57Z
dc.date.issued2010
dc.departmentFakülteler, Mühendislik Fakültesi, Çevre Mühendisliği Bölümü
dc.description.abstractPolyvinylferrocene (PVF) was used as a mediator for the fabrication of a horseradish peroxidase (HRP)-modified electrode to detect phenol derivatives via a composite polymeric matrix of conducting polypyrrole (PPy). Through an electropolymerization process, enzyme HRP was entrapped with PPy in a three-electrode system onto a glassy carbon electrode previously covered with PVF, resulting in a composite polymeric matrix. Steady-state amperometric measurements were performed at -200 mV vs. Ag/AgCl in aqueous phosphate buffer containing NaCl 0.1 M (pH 6.8) in the presence of hydrogen peroxide. The response of the HRP-modified PVF electrode was investigated for various phenol derivatives, which were 4-chlorophenol, phenol, catechol, hydroquinone, 2-aminophenol, pyrogallol, m-cresol, and 4-methoxyphenol. Analytical parameters for the fabricated PVF electrode were obtained from the calibration curves. The highest sensitivity was obtained from the calibration of 4-chlorophenol as 29.91 nA/mu M. The lowest detection limit was found to be 0.22 mu M (S/N = 3) for catechol, and the highest detection limit was found to be 0.79 mu M (S/N = 3) for 4-methoxyphenol among the tested derivatives. The biosensor can reach 95% of steady-state current in about 5 min. The electrode is stable for 2 months at 4 A degrees C.
dc.description.sponsorshipGYTE
dc.description.sponsorshipThe authors are grateful to the GYTE Research Fund for its financial support of this work.
dc.identifier.doi10.1007/s12010-009-8534-y
dc.identifier.endpage867
dc.identifier.issn0273-2289
dc.identifier.issn1559-0291
dc.identifier.issue3
dc.identifier.pmid19224403
dc.identifier.scopus2-s2.0-77949287575
dc.identifier.scopusqualityQ2
dc.identifier.startpage856
dc.identifier.urihttps://doi.org/10.1007/s12010-009-8534-y
dc.identifier.urihttps://hdl.handle.net/20.500.14854/11812
dc.identifier.volume160
dc.identifier.wosWOS:000273845900018
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherSpringer
dc.relation.ispartofApplied Biochemistry and Biotechnology
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20251020
dc.subjectPhenol biosensor
dc.subjectConducting polymer
dc.subjectHRP
dc.subjectPVF
dc.subjectPolypyrrole
dc.titleAmperometric Phenol Biosensor Based on Horseradish Peroxidase Entrapped PVF and PPy Composite Film Coated GC Electrode
dc.typeArticle

Dosyalar