Amperometric Phenol Biosensor Based on Horseradish Peroxidase Entrapped PVF and PPy Composite Film Coated GC Electrode
| dc.contributor.author | Sulak, Meral Topcu | |
| dc.contributor.author | Erhan, Elif | |
| dc.contributor.author | Keskinler, Buelent | |
| dc.date.accessioned | 2025-10-29T11:30:57Z | |
| dc.date.issued | 2010 | |
| dc.department | Fakülteler, Mühendislik Fakültesi, Çevre Mühendisliği Bölümü | |
| dc.description.abstract | Polyvinylferrocene (PVF) was used as a mediator for the fabrication of a horseradish peroxidase (HRP)-modified electrode to detect phenol derivatives via a composite polymeric matrix of conducting polypyrrole (PPy). Through an electropolymerization process, enzyme HRP was entrapped with PPy in a three-electrode system onto a glassy carbon electrode previously covered with PVF, resulting in a composite polymeric matrix. Steady-state amperometric measurements were performed at -200 mV vs. Ag/AgCl in aqueous phosphate buffer containing NaCl 0.1 M (pH 6.8) in the presence of hydrogen peroxide. The response of the HRP-modified PVF electrode was investigated for various phenol derivatives, which were 4-chlorophenol, phenol, catechol, hydroquinone, 2-aminophenol, pyrogallol, m-cresol, and 4-methoxyphenol. Analytical parameters for the fabricated PVF electrode were obtained from the calibration curves. The highest sensitivity was obtained from the calibration of 4-chlorophenol as 29.91 nA/mu M. The lowest detection limit was found to be 0.22 mu M (S/N = 3) for catechol, and the highest detection limit was found to be 0.79 mu M (S/N = 3) for 4-methoxyphenol among the tested derivatives. The biosensor can reach 95% of steady-state current in about 5 min. The electrode is stable for 2 months at 4 A degrees C. | |
| dc.description.sponsorship | GYTE | |
| dc.description.sponsorship | The authors are grateful to the GYTE Research Fund for its financial support of this work. | |
| dc.identifier.doi | 10.1007/s12010-009-8534-y | |
| dc.identifier.endpage | 867 | |
| dc.identifier.issn | 0273-2289 | |
| dc.identifier.issn | 1559-0291 | |
| dc.identifier.issue | 3 | |
| dc.identifier.pmid | 19224403 | |
| dc.identifier.scopus | 2-s2.0-77949287575 | |
| dc.identifier.scopusquality | Q2 | |
| dc.identifier.startpage | 856 | |
| dc.identifier.uri | https://doi.org/10.1007/s12010-009-8534-y | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14854/11812 | |
| dc.identifier.volume | 160 | |
| dc.identifier.wos | WOS:000273845900018 | |
| dc.identifier.wosquality | Q2 | |
| dc.indekslendigikaynak | Web of Science | |
| dc.indekslendigikaynak | Scopus | |
| dc.indekslendigikaynak | PubMed | |
| dc.language.iso | en | |
| dc.publisher | Springer | |
| dc.relation.ispartof | Applied Biochemistry and Biotechnology | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.snmz | KA_WOS_20251020 | |
| dc.subject | Phenol biosensor | |
| dc.subject | Conducting polymer | |
| dc.subject | HRP | |
| dc.subject | PVF | |
| dc.subject | Polypyrrole | |
| dc.title | Amperometric Phenol Biosensor Based on Horseradish Peroxidase Entrapped PVF and PPy Composite Film Coated GC Electrode | |
| dc.type | Article |








