The robust curve-fitting based method for coordinated voltage regulation with distributed generator and OLTC in distribution network

dc.contributor.authorTuncel, Suleyman
dc.contributor.authorGözel, Tuba
dc.date.accessioned2025-10-29T11:30:33Z
dc.date.issued2023
dc.departmentFakülteler, Mühendislik Fakültesi, Elektronik Mühendisliği Bölümü
dc.description.abstractThe voltage violation in distribution networks may occur frequently due to the rising integration of flexible demands and supplies. In this paper, the reactive power of the inverter -based distributed generator (DG) and OLTC tap position are adjusted for voltage regulation in coordinated manner. Firstly, the reactive power adjustment for the voltage regulation has been car-ried out by use of the DG reactive power capacity. Afterwards, the tap position of the OLTC has been changed to regulate the bus voltage that has a voltage violation problem in the case of insuf-ficient reactive power capacity of the DG inverter. The value of the distributed generator reactive power output that regulates the voltage on the bus that has a voltage violation is found with pro-posed curve-fitting method and tested with the Grid Search, Artificial Bee Colony methods. The proposed method derives mathematical expressions between DG reactive power output and bus voltages as quadratic equations by curve-fitting technique. Moreover, addition to inherent upper and lower reactive power limits of the DG inverter, they are determined by the proposed curve -fitting based technique while considering voltage constraints on all buses. Proposed method is much faster than other two methods because of its plain structure and gives adequate accurate results.& COPY; 2023 THE AUTHORS. Published by Elsevier BV on behalf of Faculty of Engineering, Alexandria University. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/ licenses/by-nc-nd/4.0/).
dc.identifier.doi10.1016/j.aej.2023.05.086
dc.identifier.endpage259
dc.identifier.issn1110-0168
dc.identifier.issn2090-2670
dc.identifier.orcid0000-0003-4798-0635
dc.identifier.orcid0000-0003-4565-2590
dc.identifier.scopus2-s2.0-85161282066
dc.identifier.scopusqualityQ1
dc.identifier.startpage243
dc.identifier.urihttps://doi.org/10.1016/j.aej.2023.05.086
dc.identifier.urihttps://hdl.handle.net/20.500.14854/11629
dc.identifier.volume75
dc.identifier.wosWOS:001018955400001
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherElsevier
dc.relation.ispartofAlexandria Engineering Journal
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WOS_20251020
dc.subjectVoltage regulation
dc.subjectDistributed generator
dc.subjectVAr-Volt control
dc.subjectCurve -fitting
dc.subjectReactive power adjustment
dc.subjectOLTC
dc.titleThe robust curve-fitting based method for coordinated voltage regulation with distributed generator and OLTC in distribution network
dc.typeArticle

Dosyalar