Development and characterization of a nitrite biosensor based on NirB nitrite reductase for environmental monitoring

dc.contributor.authorErdogan, Esra Mese
dc.contributor.authorDuran, Afra Gulsum
dc.contributor.authorYilmaz, Hilal
dc.contributor.authorErgenekon, Pınar
dc.contributor.authorÖzkan, Melek
dc.date.accessioned2025-10-29T11:32:54Z
dc.date.issued2025
dc.departmentFakülteler, Mühendislik Fakültesi, Çevre Mühendisliği Bölümü
dc.description.abstractNitrite is prevalent both in the natural environment and the human body. However, high concentrations of nitrite can threaten the ecosystem, and sensitive detection of nitrite is of great significance for the environment and human health. Nitrite measurement in environmental samples can be challenging due to the interference of the coexisting ions. Enzyme-based biosensors with their substrate-specific bioagents have a high potential for environmental monitoring and speedy on-site detection. The discovery of novel enzymes specific to environmental pollutants is important for the development of biosensors with high specificity and low interference. The recombinant assimilatory nitrite reductase (NirB) enzyme of Escherichia coli was used in the present study to generate an electrochemical amperometric nitrite biosensor, and its characteristics were improved for nitrite measurement in environmental samples. The NirB/MWCNTs/CHIT/MV/GC electrode was prepared by enzyme immobilization in methyl viologen-modified carbon nanotube-chitosan layers. Increasing the amount of chitosan to 32 ng in the composite matrix improved the sensitivity (6965 mA/M.cm-2) and LOD (0.22 +/- 0.07 mu M) of the electrode in PBS. The biosensor did not show any cathodic response to contaminants, including sulfite, ammonium, formate, acetate, chlorine, or sulfate, but to nitrate. A 17% decrease in the response to nitrite was observed when all the tested contaminants were included in the working buffer. Rainwater and seawater samples were used to test biosensor accuracy. The LOD of the biosensor for two different rainwater samples and a seawater sample was measured as 1.21 +/- 0.24, 1.89 +/- 0.28, and 1.54 +/- 0.33 mu M, respectively. The sensor provides accurate results when the nitrite concentration of the environmental sample is above the respective LOD levels. The NirB-based nitrite biosensor developed in this study may offer a wide range of potential applications in environmental monitoring and food safety.
dc.description.sponsorshipScientific and Technological Research Council of Turkiye [TUBITAK 120Z412]
dc.description.sponsorshipThis work was supported by the Scientific and Technological Research Council of Turkiye [TUBITAK 120Z412].
dc.identifier.doi10.1007/s10661-025-14427-2
dc.identifier.issn0167-6369
dc.identifier.issn1573-2959
dc.identifier.issue9
dc.identifier.pmid40770513
dc.identifier.scopus2-s2.0-105012727697
dc.identifier.scopusqualityQ2
dc.identifier.urihttps://doi.org/10.1007/s10661-025-14427-2
dc.identifier.urihttps://hdl.handle.net/20.500.14854/12147
dc.identifier.volume197
dc.identifier.wosWOS:001545426000001
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherSpringer
dc.relation.ispartofEnvironmental Monitoring and Assessment
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20251020
dc.subjectAmperometric biosensor
dc.subjectElectrochemical sensor
dc.subjectNitrite
dc.subjectNitrite reductase
dc.subjectNirB
dc.titleDevelopment and characterization of a nitrite biosensor based on NirB nitrite reductase for environmental monitoring
dc.typeArticle

Dosyalar