Impact of thermal modification of carbon felt on the performance of oxygen reduction reaction and mineralisation of dye in on-line electro fenton system

dc.contributor.authorErgan, Basak Temur
dc.contributor.authorSoybelli, Mert
dc.contributor.authorGengec, Erhan
dc.date.accessioned2025-10-29T11:17:15Z
dc.date.issued2023
dc.departmentGebze Teknik Üniversitesi
dc.description.abstractCarbon felt (CF) is frequently used as an electrode in various processes of oxygen reduction reactions (ORR) and water treatment. Therefore, it is critical to increasing the performance of this material in ORR. In this study, the effect of the thermal modification, which is a simple and low-cost process, was examined. For testing the hydrogen peroxide generation efficiencies and the mineralisation of Acid Orange 7 (AO7) dye, the modified CF electrodes (under 0-900 degrees C and N-2 atmosphere for 1 hour) were used as cathodes with Ti/RuO2-IrO2-TiO2 as anode and saturated calomel electrode (SCE) as a reference electrode. In addition, to find the optimum Electro-Fenton (EF) process parameters, the potential of the cathode (0.8-3.0 V), pH (3.0-9.0), Fe2+ concentration (0.2-1.0 mM) and electrolyte (sodium sulphate) concentration (10-500 mM) were investigated. The highest efficiencies in dye and TOC removal were achieved at 0.8 V, 50 mM of electrolyte concentration with 0.3 mM of Fe2+ by using CF modified at 900 degrees C as 96.26% at 10 min and 91.83% at 120 min, respectively. Besides, the modification process was increased the electroactive surface area (41.70%) and crystallite size (22.69%) of the electrode. Thus, more effective treatment was achieved. Thanks to the modification, the electrical energy and electrochemical energy saving are approximately 23.87% and 70.22%, respectively. On the other hand, a kinetic study was conducted with a large number of data coming from the on-line analysis system, which is different from most systems in the literature. At the end of the kinetic study, it was revealed that EF systems could not be explained by a single kinetic equation. It was found that the EF system has two different rate equations (first order and pseudo first order) with high correlation coefficients (R-2 = 0.9965 and 9920).
dc.description.sponsorshipTUBITAK scientific research project [:115Y305]
dc.description.sponsorshipWe thank the TUBITAK scientific research project (Project Number:115Y305) for funding the research project.
dc.identifier.doi10.1080/03067319.2021.2015341
dc.identifier.endpage9746
dc.identifier.issn0306-7319
dc.identifier.issn1029-0397
dc.identifier.issue20
dc.identifier.orcid0000-0003-3666-0791
dc.identifier.scopus2-s2.0-85121852878
dc.identifier.scopusqualityQ1
dc.identifier.startpage9730
dc.identifier.urihttps://doi.org/10.1080/03067319.2021.2015341
dc.identifier.urihttps://hdl.handle.net/20.500.14854/7955
dc.identifier.volume103
dc.identifier.wosWOS:000734824200001
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherTaylor & Francis Ltd
dc.relation.ispartofInternational Journal of Environmental Analytical Chemistry
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WOS_20251020
dc.subjectCarbon felt
dc.subjectthermal modification
dc.subjectoxygen reduction reaction
dc.subjectonline electro fenton system
dc.subjectAcid Orange 7
dc.subjectcylindrical cathode
dc.titleImpact of thermal modification of carbon felt on the performance of oxygen reduction reaction and mineralisation of dye in on-line electro fenton system