Novel Coumarin Substituted Water Soluble Cyclophosphazenes as Turn-Off Type Fluorescence Chemosensors for Detection of Fe3+ ions in Aqueous Media

dc.contributor.authorCiftci, Gonul Yenilmez
dc.contributor.authorSenkuytu, Elif
dc.contributor.authorBulut, Mustafa
dc.contributor.authorDurmuş, Mahmut
dc.date.accessioned2025-10-29T11:32:41Z
dc.date.issued2015
dc.departmentFakülteler, Temel Bilimler Fakültesi, Kimya Bölümü
dc.description.abstractIn the present work, 3-[2-(diethylamino)ethyl]-7-oxy-4-methylcoumarin substituted cyclotriphosphazene (4) and cyclotetraphosphazene (5) derivatives were synthesized by the reactions of hexachlorocyclotriphosphazene (1) or octachlorocyclotetraphosphazene (2) with 3-[2-(diethylamino)ethyl]-7-hydroxy-4-methylcoumarin (3) for the first time. The quaternized cationic (6 and 7) and zwitterionic (8 and 9) derivatives of these compounds (4 and 5) were obtained by the reactions of dimethyl sulfate and 1,3-propanesultone, respectively. All newly synthesized cyclophosphazene compounds (4-9) were fully characterized by elemental analysis and general spectroscopic techniques such as FT-IR, P-31-NMR, H-1-NMR and MALDI-TOF mass. All these coumarin substituted cyclophosphazene compounds (4-9) were soluble in most of organic solvents and quaternized ionic and zwitterionic compounds (6-9) also showed excellent solubility in water. The fluorescence behaviors of novel cyclophosphazene compounds were investigated in methanol and water solutions. The chemosensor properties of newly synthesized water soluble quaternized ionic and zwitterionic cyclotriphosphazene and cyclotetraphosphazene derivatives (6-9) were investigated in aqueous media. These cyclophosphazene derivatives showed fluorescence chemosensor behavior with high selectivity for Fe3+ ions in aqueous solution.
dc.description.sponsorshipGebze Technical University Research Fund
dc.description.sponsorshipThe authors would like to thanks the Gebze Technical University Research Fund for partial support.
dc.identifier.doi10.1007/s10895-015-1672-4
dc.identifier.endpage1830
dc.identifier.issn1053-0509
dc.identifier.issn1573-4994
dc.identifier.issue6
dc.identifier.orcid0000-0002-3579-8062
dc.identifier.pmid26420400
dc.identifier.scopus2-s2.0-84946898476
dc.identifier.scopusqualityQ3
dc.identifier.startpage1819
dc.identifier.urihttps://doi.org/10.1007/s10895-015-1672-4
dc.identifier.urihttps://hdl.handle.net/20.500.14854/12067
dc.identifier.volume25
dc.identifier.wosWOS:000364960800029
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherSpringer/Plenum Publishers
dc.relation.ispartofJournal of Fluorescence
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20251020
dc.subjectCyclophosphazene
dc.subjectCoumarin
dc.subjectWater soluble
dc.subjectChemosensor
dc.subjectFe3+ ions
dc.titleNovel Coumarin Substituted Water Soluble Cyclophosphazenes as Turn-Off Type Fluorescence Chemosensors for Detection of Fe3+ ions in Aqueous Media
dc.typeArticle

Dosyalar