Power Loss Modes of Building-Integrated Photovoltaic Modules: An Analytical Approach Using Outdoor I - V Curves

dc.contributor.authorGök, Abdülkerim
dc.contributor.authorOzkalay, Ebrar
dc.contributor.authorFriesen, Gabi
dc.contributor.authorFrontini, Francesco
dc.date.accessioned2025-10-29T11:15:48Z
dc.date.issued2021
dc.departmentFakülteler, Temel Bilimler Fakültesi, Matematik Bölümü
dc.departmentFakülteler, Mühendislik Fakültesi, Malzeme Bilimi ve Mühendisliği Bölümü
dc.description.abstractUsing outdoor time-series I-V curves, the analytic I-sc-V-oc method was applied to glass/backsheet and glass/glass crystalline silicon module constructions with ventilated and insulated mounting configurations in order to explore contributing factors to degradation in the power performance. The rates of power loss modes; namely uniform current, recombination, series resistance, and current mismatch, were assessed for each module and configuration. The effect of thermal insulation was evident in the glass/backsheet module with an ethylene-vinyl acetate type encapsulant: the observed loss in the performance was chiefly originated from the resistive loss. The cell and metallization defects induced by thermo-mechanical stresses were believed to be main reasons. However, the double glass module with a polyvinyl-butyral type encapsulant was more resistant to thermal effects: a large increase in the uniform current, compensated by the resistive loss, was the main driver for the observed gain in the performance. For all modules and configurations, the calculated power loss mode rates were compared with the reported performance loss rates and they were found to be in close agreement. This analytic technique was found to be a powerful method in order to determine and quantify the individual contributions from specific power loss modes to overall module performance.
dc.description.sponsorshipSwiss National Science Foundation [COST IZCOZ0_182967/1]
dc.description.sponsorshipCOST Action PEARL PV Project [CA 61235-Performance]
dc.description.sponsorshipThis work was supported in part by the Swiss National Science Foundation under Grant COST IZCOZ0_182967/1. The work of Abdulkerim Gok was supported by a Grant from the COST Action PEARL PV Project (CA 61235-Performance, and Reliability of Photovoltaic Systems: Evaluations of Large-Scale Monitoring Data) for the Short-Term Scientific Mission at the University of Applied Sciences, and Arts of Southern Switzerland (SUPSI).
dc.identifier.doi10.1109/JPHOTOV.2021.3060719
dc.identifier.endpage796
dc.identifier.issn2156-3381
dc.identifier.issn2156-3403
dc.identifier.issue3
dc.identifier.orcid0000-0003-0119-9261
dc.identifier.orcid0000-0002-3827-5259
dc.identifier.orcid0000-0003-3433-7106
dc.identifier.orcid0000-0002-6554-8937
dc.identifier.scopus2-s2.0-85102656288
dc.identifier.scopusqualityQ1
dc.identifier.startpage789
dc.identifier.urihttps://doi.org/10.1109/JPHOTOV.2021.3060719
dc.identifier.urihttps://hdl.handle.net/20.500.14854/7249
dc.identifier.volume11
dc.identifier.wosWOS:000641964300029
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherIEEE-Inst Electrical Electronics Engineers Inc
dc.relation.ispartofIEEE Journal of Photovoltaics
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20251020
dc.subjectAnalytic I-sc-V-oc method
dc.subjectbuilding-integrated photovoltaics (BIPV)
dc.subjectoutdoor I - V curves
dc.subjectpower loss modes
dc.subjectthermal insulation
dc.subjectyear-over-year (YoY) regression
dc.titlePower Loss Modes of Building-Integrated Photovoltaic Modules: An Analytical Approach Using Outdoor I - V Curves
dc.typeArticle

Dosyalar