How does arsenic speciation (arsenite and arsenate) in groundwater affect the performance of an aerated electrocoagulation reactor and human health risk?

dc.contributor.authorGoren, Aysegul Yagmur
dc.contributor.authorKobya, Mehmet
dc.contributor.authorKhataee, Alireza
dc.date.accessioned2025-10-29T11:23:07Z
dc.date.issued2022
dc.departmentFakülteler, Mühendislik Fakültesi, Çevre Mühendisliği Bölümü
dc.description.abstractArsenic (As) occurrence in water resources has become one of the most critical environmental problems worldwide. The detrimental health impacts on humans have been reported due to the consumption of As-contaminated groundwater resources. Consumption of As-containing water over the long term can cause arsenicosis and chronic effects on human health due to its toxicity. Several treatment processes are available for As removals such as coagulation, ion exchange, adsorption, and membrane technologies but they have various major drawbacks. In the present work, therefore, an aerated electrocoagulation (EC) system with aluminum anodes was operated for simultaneous arsenate (As(V)) and arsenite (As(III)) removal to overcome the disadvantages of other processes such as, sludge formation, difficulties in operation, high operating costs, high energy consumption, and the requirement of pre-treatment process and to enhance the conventional EC process. The combined effects of the applied current (0.075-0.3 A), aeration rate (0-61,/min), pH (6.5-8.5), and As speciation (As(V)-As(III)) were studied on As removal efficiency. The findings revealed that As removal mostly depended on the airflow rate and the applied current in the EC system. The highest As removal efficiency (99.1%) was obtained at an airflow rate of 6 L/min, a pH of 6.5, an initial As (V) concentration of 200 mu g/L, and a current of 0.3 A, with an energy consumption of 2.85 kWh/m(3) and an operating cost of 0.66 $/m(3). The human health risk assessment of treated water was also examined to understand the performance of the EC system. At most of the experimental runs, the chronic toxic risk (crR) and carcinogenic risk (CR) of As were within the permissible limits except for an airflow rate of 0-2 L/min, an initial pH of 8.5, and a current of 0.075-0.15 A for high initial As (III) concentrations. Overall, the As removal performance and groundwater risk assessment show that the EC process is a promising option for industrial applications.
dc.description.sponsorshipTUBITAK (The Scientific and Technical Research Council of Turkey) [111Y103]
dc.description.sponsorshipThe authors would like to give thanks for the financial support from TUBITAK (The Scientific and Technical Research Council of Turkey, Project Number = 111Y103).
dc.identifier.doi10.1016/j.scitotenv.2021.152135
dc.identifier.issn0048-9697
dc.identifier.issn1879-1026
dc.identifier.orcid0000-0003-1114-6059
dc.identifier.pmid34864021
dc.identifier.scopus2-s2.0-85120845879
dc.identifier.scopusqualityQ1
dc.identifier.urihttps://doi.org/10.1016/j.scitotenv.2021.152135
dc.identifier.urihttps://hdl.handle.net/20.500.14854/9283
dc.identifier.volume808
dc.identifier.wosWOS:000740227700012
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherElsevier
dc.relation.ispartofScience of the Total Environment
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20251020
dc.subjectArsenite
dc.subjectArsenate
dc.subjectGroundwater
dc.subjectElectrocoagulation
dc.subjectAl balls
dc.subjectHealth risk
dc.titleHow does arsenic speciation (arsenite and arsenate) in groundwater affect the performance of an aerated electrocoagulation reactor and human health risk?
dc.typeArticle