A determination of interlaminar shear strength for two-layered GFRP/CFRP flexing carriers in a fibre-reinforced composite structure

dc.contributor.authorTas, Zakir
dc.date.accessioned2025-10-29T11:09:15Z
dc.date.issued2007
dc.departmentGebze Teknik Üniversitesi
dc.description.abstractInterlaminar fracture is the way of failure which occurs most frequently in fibre-reinforced composite structures. The reasons which lead to interlaminar fracture are faults in manufacture, damage caused in use, and interlaminar stresses. In case of loads, delaminations appear in fibre-reinforced composites. Interlaminar shear strength is a measure of delamination. This article examines the interlaminar shear strength of multi-layered flexing carriers in a fibre hybrid construction from GFRP and CFRP. The test bars made of GFRP and CFRP were manufactured in two different ways: by integrating manufacture in an autoclaving process and by bonding after an individual manufacture of the composite components. A determination of interlaminar shear strength was made by means of the three-point bending test.
dc.identifier.doi10.3139/147.100344
dc.identifier.endpage272
dc.identifier.issn0032-678X
dc.identifier.issue6
dc.identifier.scopus2-s2.0-34547288877
dc.identifier.scopusqualityQ4
dc.identifier.startpage259
dc.identifier.urihttps://doi.org/10.3139/147.100344
dc.identifier.urihttps://hdl.handle.net/20.500.14854/5740
dc.identifier.volume44
dc.identifier.wosWOS:000248535900001
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.institutionauthorTas, Zakir
dc.language.isode
dc.publisherCarl Hanser Verlag
dc.relation.ispartofPraktische Metallographie-Practical Metallography
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20251020
dc.titleA determination of interlaminar shear strength for two-layered GFRP/CFRP flexing carriers in a fibre-reinforced composite structure