Development of Amperometric Biosensor for Phenolic Compounds Using a Modified Electrode with Poly(GMA-co-MTM) and Laccase
| dc.contributor.author | Sulak, Meral Topcu | |
| dc.contributor.author | Erhan, Elif | |
| dc.contributor.author | Keskinler, Bülent | |
| dc.contributor.author | Yilmaz, Faruk | |
| dc.contributor.author | Celik, Asuman | |
| dc.date.accessioned | 2025-10-29T11:12:52Z | |
| dc.date.issued | 2010 | |
| dc.department | Fakülteler, Mühendislik Fakültesi, Çevre Mühendisliği Bölümü | |
| dc.department | Fakülteler, Mühendislik Fakültesi, Kimya Mühendisliği Bölümü | |
| dc.description.abstract | A new polymeric matrix, the copolymer of 3-thienylmethyl methacrylate (MTM) and glycidyl methacrylate (GMA), was used to develop a phenol biosensor based on laccase (TvLac). Chemical immobilization of the enzyme, TvLac, was achieved via the epoxy moiety of GMA onto the GMA-co-MTM coated glassy carbon electrode. GC/(GMA-co-MTM)/TvLac working electrode was investigated for the parameters of linear range, sensitivity, stability, pH and detection limit. Amperometric response was measured as a function of concentration of phenolic compounds, at a fixed bias voltage of -200 mV. The sensitivity in the linear range increased in this order with the GC/(GMA-co-MTM)/TvLac: 3-Chlorophenol > 2-Chlorophenol > 2,6-Dimethoxyphenol > Catechol > 4Methoxyphenol > 4-Chlorophenol > Phenol > Hydroquinone > 2,4-Dichlorophenol > p-Benzoquinone. The biosensor exhibited good sensitivity, stability for the tested phenolics compared to the reported working electrodes. It retained 65% of its initial activity after using for 300 measurements in one month. | |
| dc.description.sponsorship | GYTE Research Fund | |
| dc.description.sponsorship | The authors are grateful to GYTE Research Fund for its financial support of this work. | |
| dc.identifier.doi | 10.1166/sl.2010.1260 | |
| dc.identifier.endpage | 267 | |
| dc.identifier.issn | 1546-198X | |
| dc.identifier.issn | 1546-1971 | |
| dc.identifier.issue | 2 | |
| dc.identifier.orcid | 0000-0002-3509-1497 | |
| dc.identifier.scopus | 2-s2.0-77954900293 | |
| dc.identifier.scopusquality | N/A | |
| dc.identifier.startpage | 262 | |
| dc.identifier.uri | https://doi.org/10.1166/sl.2010.1260 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14854/6478 | |
| dc.identifier.volume | 8 | |
| dc.identifier.wos | WOS:000276808500009 | |
| dc.identifier.wosquality | Q3 | |
| dc.indekslendigikaynak | Web of Science | |
| dc.indekslendigikaynak | Scopus | |
| dc.language.iso | en | |
| dc.publisher | Amer Scientific Publishers | |
| dc.relation.ispartof | Sensor Letters | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.snmz | KA_WOS_20251020 | |
| dc.subject | Laccase | |
| dc.subject | Phenol | |
| dc.subject | Amperometric Biosensor | |
| dc.subject | Enzyme Electrodes | |
| dc.subject | Polymeric Matrix | |
| dc.title | Development of Amperometric Biosensor for Phenolic Compounds Using a Modified Electrode with Poly(GMA-co-MTM) and Laccase | |
| dc.type | Article |