Influence of membrane fouling reducers (MFRs) on filterability of disperse mixed liquor of Jet Loop Bioreactors

dc.contributor.authorKoseoglu-Imer, Derya Yuksel
dc.contributor.authorDizge, Nadir
dc.contributor.authorKaragündüz, Ahmet
dc.contributor.authorKeskinler, Bülent
dc.date.accessioned2025-10-29T11:30:15Z
dc.date.issued2011
dc.departmentFakülteler, Mühendislik Fakültesi, Çevre Mühendisliği Bölümü
dc.description.abstractThe effects of membrane fouling reducers (MFRs) (the cationic polyelectrolyte (CPE) and FeCl3) on membrane fouling were studied in a lab-scale jet loop submerged membrane bioreactor (JL-SMBR) system. The optimum dosages of MFRs (CPE dosage = 20 mg g(-1) MLSS, FeCl3 dosage = 14 mg g(-1) MLSS) were continuously fed to JL-SMBR system. The soluble and bound EPS concentrations as well as MLSS concentration in the mixed liquor of JL-SMBR were not changed substantially by the addition of MFRs. However, significant differences were observed in particle size and relative hydrophobicity. Filtration tests were performed by using different membrane types (polycarbonate (PC) and nitrocellulose mixed ester (ME)) and various pore sizes (0.45-0.22-0.1 mu m). The steady state fluxes (J(ss)) of membranes increased at all membranes after MFRs addition to JL-SMBR. The filtration results showed that MFRs addition was an effective approach in terms of improvement in filtration performance for both membrane types. (C) 2011 Elsevier Ltd. All rights reserved.
dc.description.sponsorshipTUBITAK, the Scientific and Technological Research Council of Turkey [108Y129]
dc.description.sponsorshipThis study was financially supported by the TUBITAK, the Scientific and Technological Research Council of Turkey (Project No: 108Y129).
dc.identifier.doi10.1016/j.biortech.2011.04.024
dc.identifier.endpage6849
dc.identifier.issn0960-8524
dc.identifier.issn1873-2976
dc.identifier.issue13
dc.identifier.orcid0000-0002-8406-0718
dc.identifier.orcid0000-0003-3023-4556
dc.identifier.pmid21536431
dc.identifier.scopus2-s2.0-79956350938
dc.identifier.scopusqualityQ1
dc.identifier.startpage6843
dc.identifier.urihttps://doi.org/10.1016/j.biortech.2011.04.024
dc.identifier.urihttps://hdl.handle.net/20.500.14854/11486
dc.identifier.volume102
dc.identifier.wosWOS:000292487300009
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherElsevier Sci Ltd
dc.relation.ispartofBioresource Technology
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20251020
dc.subjectJet loop bioreactor (JLBR)
dc.subjectMembrane fouling
dc.subjectExtracellular polymeric substances (EPS)
dc.subjectMembrane fouling reducer (MFR)
dc.titleInfluence of membrane fouling reducers (MFRs) on filterability of disperse mixed liquor of Jet Loop Bioreactors