Experimental determination of optimal clamping torque for AB-PEM fuel cell

dc.contributor.authorUl Hassan, Noor
dc.contributor.authorKilic, Murat
dc.contributor.authorOkumus, Emin
dc.contributor.authorTunaboylu, Bahadir
dc.contributor.authorSoydan, Ali Murat
dc.date.accessioned2025-10-29T11:07:48Z
dc.date.issued2016
dc.departmentGebze Teknik Üniversitesi
dc.description.abstractPolymer electrolyte Membrane (PEM) fuel cell is an electrochemical device producing electricity by the reaction of hydrogen and oxygen without combustion. PEM fuel cell stack is provided with an appropriate clamping torque to prevent leakage of reactant gases and to minimize the contact resistance between gas diffusion media (GDL) and bipolar plates. GDL porous structure and gas permeability is directly affected by the compaction pressure which, consequently, drastically change the fuel cell performance. Various efforts were made to determine the optimal compaction pressure and pressure distributions through simulations and experimentation. Lower compaction pressure results in increase of contact resistance and also chances of leakage. On the other hand, higher compaction pressure decreases the contact resistance but also narrows down the diffusion path for mass transfer from gas channels to the catalyst layers, consequently, lowering cell performance. The optimal cell performance is related to the gasket thickness and compression pressure on GDL. Every stack has a unique assembly pressure due to differences in fuel cell components material and stack design. Therefore, there is still need to determine the optimal torque value for getting the optimal cell performance. This study has been carried out in continuation of development of Air breathing PEM fuel cell for small Unmanned Aerial Vehicle (UAV) application. Compaction pressure at minimum contact resistance was determined and clamping torque value was calculated accordingly. Single cell performance tests were performed at five different clamping torque values i.e 0.5, 1.0, 1.5, 2.0 and 2.5 N m, for achieving optimal cell performance. Clamping pressure distribution tests were also performed at these torque values to verify uniform pressure distribution at optimal torque value. Experimental and theoretical results were compared for making inferences about optimal cell performance. A clamping torque value of 1.5 N m was determined experimentally to be the best for getting optimal performance as well as uniform pressure distribution for this specific fuel cell.
dc.identifier.doi10.5599/jese.198
dc.identifier.endpage16
dc.identifier.issn1847-9286
dc.identifier.issue1
dc.identifier.scopus2-s2.0-84991260278
dc.identifier.scopusqualityQ3
dc.identifier.startpage9
dc.identifier.urihttps://doi.org/10.5599/jese.198
dc.identifier.urihttps://hdl.handle.net/20.500.14854/5064
dc.identifier.volume6
dc.identifier.wosWOS:000409209900003
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherInt Assoc Physical Chemists-Iapc
dc.relation.ispartofJournal of Electrochemical Science and Engineering
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WOS_20251020
dc.subjectAir breathing PEM fuel cell
dc.subjectStack clamping torque
dc.subjectCompaction pressure
dc.subjectContact resistance
dc.subjectOptimal cell performance
dc.titleExperimental determination of optimal clamping torque for AB-PEM fuel cell