Seismic performance of elevated steel silos during Van earthquake, October 23, 2011

dc.contributor.authorUckan, Eren
dc.contributor.authorAkbaş, Bülent
dc.contributor.authorShen, Jay
dc.contributor.authorWen, Rou
dc.contributor.authorTurandar, Kenan
dc.contributor.authorErdik, Mustafa
dc.date.accessioned2025-10-29T11:31:17Z
dc.date.issued2015
dc.departmentFakülteler, Mühendislik Fakültesi, İnşaat Bölümü
dc.description.abstractSilos are commonly used industrial structures to store dry/granular materials like cement or wheat. A typical silo consists of a vertical steel tank supported by a braced steel frame which rests on concrete support. Due to unloading purposes, the tank is generally located at an elevated position. This makes the structure vulnerable to axial loads in columns due to excessive overturning moments generated at the base of the structure. During the October 23, 2011 Van earthquake in Turkey, many silos collapsed either due to column buckling or foundation problems. In this paper, the field observations regarding the seismic performance of silos after the Van earthquake are first summarized. Then, the seismic performances of two steel-elevated silos located in the earthquake region are studied. One of the silos survived the earthquake by some minor damages in the form of buckling (at bottom horizontal brace) and spalling of concrete support, while the other silo remained undamaged. Nonlinear dynamic time history analyses are performed to evaluate the seismic performances of both silos. As the input ground motion, the recorded ground motion from a temporary aftershock station (about 2 km away from the silos) in the second earthquake is used. Analyses indicate that design and construction quality of elevated silos determine the seismic performance. Finally, recommendations are given to improve the seismic performance of new constructions.
dc.description.sponsorshipDirectory of Scientific Research Project of Bosphorus University [BAP5715]
dc.description.sponsorshipDirectorate of Kandilli Observatory and Earthquake Research Institute, Bosphorus University (KOERI).
dc.description.sponsorshipThis research was supported by the Directory of Scientific Research Project of Bosphorus University (Grant # BAP5715) and Directorate of Kandilli Observatory and Earthquake Research Institute, Bosphorus University (KOERI).
dc.identifier.doi10.1007/s11069-014-1319-9
dc.identifier.endpage287
dc.identifier.issn0921-030X
dc.identifier.issn1573-0840
dc.identifier.issue1
dc.identifier.scopus2-s2.0-84914815928
dc.identifier.scopusqualityQ1
dc.identifier.startpage265
dc.identifier.urihttps://doi.org/10.1007/s11069-014-1319-9
dc.identifier.urihttps://hdl.handle.net/20.500.14854/11945
dc.identifier.volume75
dc.identifier.wosWOS:000345971600013
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherSpringer
dc.relation.ispartofNatural Hazards
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20251020
dc.subjectElevated silos
dc.subjectNon-building structures
dc.subjectVan earthquake
dc.titleSeismic performance of elevated steel silos during Van earthquake, October 23, 2011
dc.typeArticle

Dosyalar