Performance Assessment of Biocompatible Metals Used in the Treatment of Femoral Neck Fractures

dc.contributor.authorÇakır, Ferit
dc.contributor.authorOzkal, Fatih Mehmet
dc.contributor.authorSensoz, Ersin
dc.date.accessioned2025-10-29T11:20:41Z
dc.date.issued2022
dc.departmentFakülteler, Mühendislik Fakültesi, İnşaat Bölümü
dc.description.abstractFemoral neck fractures (FNFs) are among the most common types of hip fractures. Particularly in young patients, these fractures require adequate fixation. These fractures, which are prevalent in elderly patients, are usually treated with implant applications. In implant applications, it is possible to find many different fixation configurations with various implant materials. The purpose of this study is to investigate the effects of metallic implant materials on fixation performance in the application of cannulated screws in an inverted triangle (CSIT), which are most preferred by orthopedic surgeons. Therefore, a femur bone with a type 2 fracture was numerically modeled and performances of CSIT implants with different biocompatible metals were investigated over nonlinear finite-element analyses (FEA). Within the study, stainless steel (SS), pure titanium (pTi), titanium alloy (Ti6Al4V), cobalt-chromium alloy (Co - Cr), and magnesium alloy (WE43) materials, frequently used as biocompatible implant materials, were taken into consideration and their performances were evaluated under static, vibration, and fatigue analyses. Throughout the comparison of analysis results and an optimality indicator formula, the optimum material was found to be the Co-Cr alloy on the basis of considered performance characteristics.
dc.identifier.doi10.1021/acsabm.2c00321
dc.identifier.endpage3022
dc.identifier.issn2576-6422
dc.identifier.issue6
dc.identifier.orcid0000-0002-5552-283X
dc.identifier.orcid0000-0003-4591-6584
dc.identifier.pmid35674244
dc.identifier.scopus2-s2.0-85132455652
dc.identifier.scopusqualityQ1
dc.identifier.startpage3013
dc.identifier.urihttps://doi.org/10.1021/acsabm.2c00321
dc.identifier.urihttps://hdl.handle.net/20.500.14854/8684
dc.identifier.volume5
dc.identifier.wosWOS:000814162500001
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherAmer Chemical Soc
dc.relation.ispartofAcs Applied Bio Materials
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WOS_20251020
dc.subjectfemoral neck fractures
dc.subjectbiocompatible metals
dc.subjectnonlinear finite-element analysis
dc.subjectcannulated screws in inverted triangle implants
dc.subjectperformance decision
dc.titlePerformance Assessment of Biocompatible Metals Used in the Treatment of Femoral Neck Fractures
dc.typeArticle

Dosyalar