Treatment of paint manufacturing wastewater by electrocoagulation
Tarih
Yazarlar
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Erişim Hakkı
Özet
Treatability of paint manufacturing wastewater (PMW) by electrocoagulation (EC) process was investigated. Effects of operating parameters for the EC process such as electrode type (Al or Fe), initial pH (2-10), current density (5-80 A/m(2)) and operating time (0-50 min) were evaluated for optimum operating conditions. The highest removal efficiencies for COD and TOC in PMW were obtained with 93% and 88% for Fe and 94% and 89% for Al electrodes at the optimum conditions (35 A/m(2), 15 min and pH 6.95). Operating costs for removal of PMW at the optimum conditions were calculated for Fe and Al electrodes as 0.187 (sic)/m(3) and 0.129 9sic)/m(3). Toxicity test was carried out to obtain information about toxic effect of the raw and treated wastewaters at optimum operating conditions. The samples measured by respirometric method contained hardly toxicities. Performance of Al electrode was better than that of Fe electrode in terms of removal efficiency and operating cost. (C) 2011 Elsevier B.V. All rights reserved.