Ultrasensitive and label free electrochemical immunosensor for detection of ROR1 as an oncofetal biomarker using gold nanoparticles assisted LDH/rGO nanocomposite

dc.contributor.authorAbolhasan, Rozita
dc.contributor.authorKhalilzadeh, Balal
dc.contributor.authorYousefi, Hadi
dc.contributor.authorSamemaleki, Sahar
dc.contributor.authorChakari-Khiavi, Forough
dc.contributor.authorGhorbani, Farzaneh
dc.contributor.authorPourakbari, Ramin
dc.date.accessioned2025-10-29T11:20:17Z
dc.date.issued2021
dc.departmentFakülteler, Mühendislik Fakültesi, Çevre Mühendisliği Bölümü
dc.description.abstractIn the present article, we developed a highly sensitive label-free electrochemical immunosensor based on NiFe-layered double hydroxides (LDH)/reduced graphene oxide (rGO)/gold nanoparticles modified glassy carbon electrode for the determination of receptor tyrosine kinase-like orphan receptor (ROR)-1. In this electrochemical immunoassay platform, NiFe-LDH/rGO was used due to great electron mobility, high specific surface area and flexible structures, while Au nanoparticles were prepared and coated on the modified electrodes to improve the detection sensitivity and ROR1 antibody immobilizing (ROR1Ab). The modification procedure was approved by using cyclic voltammetry and differential pulse voltammetry based on the response of peak current to the step by step modifications. Under optimum conditions, the experimental results showed that the immunosensor revealed a sensitive response to ROR1 in the range of 0.01-1 pg mL(-1), and with a lower limit of quantification of 10 attogram/mL (10 ag mL(-1)). Furthermore, the designed immunosensor was applied for the analysis of ROR1 in several serum samples of chronic lymphocytic leukemia suffering patients with acceptable results, and it also exhibited good selectivity, reproducibility and stability.
dc.description.sponsorshipstem cell research center, Tabriz University of Medical Sciences, Tabriz, Iran [60944]
dc.description.sponsorshipThis project was financially supported by stem cell research center, Tabriz University of Medical Sciences, Tabriz, Iran (Grant number: 60944).
dc.identifier.doi10.1038/s41598-021-94380-5
dc.identifier.issn2045-2322
dc.identifier.issue1
dc.identifier.orcid0000-0003-0099-6728
dc.identifier.orcid0000-0002-5609-8751
dc.identifier.pmid34290319
dc.identifier.scopus2-s2.0-85110965688
dc.identifier.scopusqualityQ1
dc.identifier.urihttps://doi.org/10.1038/s41598-021-94380-5
dc.identifier.urihttps://hdl.handle.net/20.500.14854/8521
dc.identifier.volume11
dc.identifier.wosWOS:000687318300047
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherNature Portfolio
dc.relation.ispartofScientific Reports
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WOS_20251020
dc.subjectTyrosine Kinase Ror1
dc.subjectBiosensors
dc.subjectExpression
dc.subjectElectrooxidation
dc.subjectNanomaterial
dc.subjectGraphene
dc.subjectAntigen
dc.subjectAcid
dc.titleUltrasensitive and label free electrochemical immunosensor for detection of ROR1 as an oncofetal biomarker using gold nanoparticles assisted LDH/rGO nanocomposite
dc.typeArticle

Dosyalar