Amperometric nitrate biosensor based on Carbon nanotube/Polypyrrole/Nitrate reductase biofilm electrode
| dc.contributor.author | Can, Faruk | |
| dc.contributor.author | Ozoner, Seyda Korkut | |
| dc.contributor.author | Ergenekon, Pınar | |
| dc.contributor.author | Erhan, Elif | |
| dc.date.accessioned | 2025-10-29T11:24:07Z | |
| dc.date.issued | 2012 | |
| dc.department | Fakülteler, Mühendislik Fakültesi, Çevre Mühendisliği Bölümü | |
| dc.description.abstract | This study describes the construction and characterization of an amperometric nitrate biosensor based on the Polypyrrole (PPy)/Carbon nanotubes (CNTs) film. Nitrate reductase (NR) was both entrapped into the growing PPy film and chemically immobilized via the carboxyl groups of CNTs to the CNT/PPy film electrode. The optimum amperometric response for nitrate was obtained in 0.1 M phosphate buffer solution (PBS), pH 7.5 including 0.1 M lithium chloride and 7 mM potassium ferricyanide with an applied potential of 0.13 V (vs. Ag/AgCl, 3 M NaCl). Sensitivity was found to be 300 nA/mM in a linear range of 0.44-1.45 mM with a regression coefficient of 0.97. The biosensor response showed a higher linear range in comparison to standard nitrate analysis methods which were tested in this study and NADH based nitrate biosensors. A minimum detectable concentration of 0.17 mM (S/N = 3) with a relative standard deviation (RSD) of 5.4% (n = 7) was obtained for the biosensor. Phenol and glucose inhibit the electrochemical reaction strictly at a concentration of 1 mu g/L and 20 mg/L, respectively. The biosensor response retained 70% of its initial response over 10 day usage period when used everyday. (C) 2011 Elsevier B.V. All rights reserved. | |
| dc.identifier.doi | 10.1016/j.msec.2011.09.004 | |
| dc.identifier.endpage | 23 | |
| dc.identifier.issn | 0928-4931 | |
| dc.identifier.issn | 1873-0191 | |
| dc.identifier.issue | 1 | |
| dc.identifier.orcid | 0000-0003-2892-6182 | |
| dc.identifier.pmid | 23177766 | |
| dc.identifier.scopus | 2-s2.0-81355160298 | |
| dc.identifier.scopusquality | N/A | |
| dc.identifier.startpage | 18 | |
| dc.identifier.uri | https://doi.org/10.1016/j.msec.2011.09.004 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14854/9777 | |
| dc.identifier.volume | 32 | |
| dc.identifier.wos | WOS:000298463800003 | |
| dc.identifier.wosquality | Q2 | |
| dc.indekslendigikaynak | Web of Science | |
| dc.indekslendigikaynak | Scopus | |
| dc.indekslendigikaynak | PubMed | |
| dc.language.iso | en | |
| dc.publisher | Elsevier Science Bv | |
| dc.relation.ispartof | Materials Science & Engineering C-Materials For Biological Applications | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.snmz | KA_WOS_20251020 | |
| dc.subject | Nitrate reductase | |
| dc.subject | Biosensor | |
| dc.subject | Mediator | |
| dc.subject | Polypyrrole | |
| dc.subject | Carbon nanotube | |
| dc.title | Amperometric nitrate biosensor based on Carbon nanotube/Polypyrrole/Nitrate reductase biofilm electrode | |
| dc.type | Article |