Investigation of temperature effects of a low-level laser source within the muscle phantom
| dc.contributor.author | Okan Durmuş, Hüseyin Okan | |
| dc.contributor.author | Gün, Neslişah | |
| dc.contributor.author | Karaböce, Baki | |
| dc.contributor.author | Seyidov, Mir Hasan Yu | |
| dc.date.accessioned | 2025-10-29T12:08:42Z | |
| dc.date.issued | 2021 | |
| dc.department | Fakülteler, Temel Bilimler Fakültesi, Fizik Bölümü | |
| dc.description.abstract | In this study, temperature effects of a low-level laser source were investigated in a muscle phantom within 20, 40, 60, and 80 seconds time intervals. A temperature meter device having a 5-channel and 10 k? negative temperature coefficient (NTC) type thermistor sensors were developed in TUBITAK UME Medical Metrology Laboratory for these special temperature measurements. The muscle phantom poured into a phantom container that was specially designed for 5-channel sensor placement and printed in a 3D printer. It has also been acoustically confirmed that the phantom has muscle phantom characteristics. As a result of this study, it is concluded that the laser source used is safe and suitable at therapy usage within the specified times in terms of the detected temperatures. © 2024 Elsevier B.V., All rights reserved. | |
| dc.identifier.doi | 10.11591/ijaas.v10.i4.pp373-377 | |
| dc.identifier.endpage | 377 | |
| dc.identifier.issn | 2252-8814 | |
| dc.identifier.issn | 2722-2594 | |
| dc.identifier.issue | 4 | |
| dc.identifier.scopus | 2-s2.0-85144070679 | |
| dc.identifier.scopusquality | Q4 | |
| dc.identifier.startpage | 373 | |
| dc.identifier.uri | https://doi.org/10.11591/ijaas.v10.i4.pp373-377 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14854/14653 | |
| dc.identifier.volume | 10 | |
| dc.indekslendigikaynak | Scopus | |
| dc.language.iso | en | |
| dc.publisher | Intelektual Pustaka Media Utama | |
| dc.relation.ispartof | International Journal of Advances in Applied Sciences | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.snmz | KA_Scopus_20251020 | |
| dc.subject | Low-level laser source | |
| dc.subject | Low-level laser therapy | |
| dc.subject | Muscle phantom | |
| dc.subject | Temperature effects | |
| dc.subject | Tissue-like materials | |
| dc.title | Investigation of temperature effects of a low-level laser source within the muscle phantom | |
| dc.type | Article |








