Application of 2E-2U method for free-field underwater calibrations of hydrophones and projectors in a reverberant laboratory test tank

dc.contributor.authorCorakci, Ata Can
dc.contributor.authorBiber, Alper
dc.contributor.authorSaydam, Talha
dc.contributor.authorAksoy, Serkan
dc.date.accessioned2025-10-29T11:16:29Z
dc.date.issued2024
dc.departmentFakülteler, Mühendislik Fakültesi, Elektronik Mühendisliği Bölümü
dc.description.abstractIn this paper, application of a Two-Equations Two-Unknowns (2E-2U) method is described for calibration of hydrophones and projectors below 1 kHz in a laboratory test tank. At low frequencies, amplitude and phase measurements for the calibration of the hydrophones and projectors in the test tank are difficult to perform since echo-free time of the laboratory test tank is not large enough due to transducer initial transients and tank wall boundary reflections. To overcome these difficulties, the 2E-2U method is applied to received (windowed) signals obtained during calibration measurements. Thus, calibration measurements become possible at a frequency down to 250 Hz. These measurements in the test tank are performed for a hydrophone and a developed flextensional projector. First, the received sensitivities for the hydrophone are calculated and validated by comparisons with pressure calibration in a closed chamber. Good agreements are obtained between the two measurement platforms, with a maximum difference of 0.5 dB and uncertainty of 1.3 dB. Then, the transmitting voltage response (TVR) of the flextensional projector is calculated and compared with the calibration data obtained from the method defined in the relevant standards. Good agreements are obtained between the two TVR data with a maximum difference of 1.1 dB and uncertainty of 1.7 dB.
dc.identifier.doi10.1088/1361-6501/ad42be
dc.identifier.issn0957-0233
dc.identifier.issn1361-6501
dc.identifier.issue8
dc.identifier.scopus2-s2.0-85192681238
dc.identifier.scopusqualityQ1
dc.identifier.urihttps://doi.org/10.1088/1361-6501/ad42be
dc.identifier.urihttps://hdl.handle.net/20.500.14854/7624
dc.identifier.volume35
dc.identifier.wosWOS:001215209800001
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherIop Publishing Ltd
dc.relation.ispartofMeasurement Science and Technology
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WOS_20251020
dc.subjectunderwater acoustics
dc.subjecthydrophone and projector calibration
dc.subject2E-2U method
dc.titleApplication of 2E-2U method for free-field underwater calibrations of hydrophones and projectors in a reverberant laboratory test tank
dc.typeArticle

Dosyalar