Investigation of electrochemical behaviour and determination of Riociguat with bare GCE and molecularly imprinted polymer-based electrochemical sensor

dc.contributor.authorHosseinzadeh, Batoul
dc.contributor.authorJadon, Nimisha
dc.contributor.authorOzcelikay-Akyildiz, Goksu
dc.contributor.authorKaya, S. Irem
dc.contributor.authorCetinkaya, Ahmet
dc.contributor.authorAtici, Esen Bellur
dc.contributor.authorOzkan, Sibel A.
dc.date.accessioned2025-10-29T11:27:58Z
dc.date.issued2024
dc.departmentFakülteler, Temel Bilimler Fakültesi, Kimya Bölümü
dc.description.abstractPulmonary Arterial Hypertension (PAH) causes death due to ventricular overload and heart failure. Calcium channel blockers, anticoagulants, digoxin and diuretics are the standards of care for PAH. Riociguat (RIO) is an oral soluble guanylate cyclase stimulator approved for the treatment of PAH by World Health Organization (WHO) Group 1 patients. In this study, the electrochemical behavior of RIO was investigated using a bare glassy carbon electrode (GCE). In addition, RIO was determined using GCE and a molecularly imprinted polymer (MIP)based electrochemical sensor. The MIP-based electrochemical sensor was prepared by photopolymerization of methacrylic acid in the presence of a basic monomer, crosslinker, target molecule, and photoinitiator. The polymer film was characterised by a scanning electron microscope (SEM) and cyclic voltammetry (CV). Under the optimized conditions, the results obtained with GCE and MIP sensor were compared. The analytical performance of GCE and MIP-based electrochemical sensors was evaluated. The linear ranges of RIO were 1.0 x 10-6 - 1.0 x 10-4 M and 1.0 x 10-13 - 1.0 x 10-12 M, with a limit of detection (LOD) of 1.40 x 10-8 M and 2.12 x 10-14 by bare GCE and MIP-based electrochemical sensor using differential pulse voltammetry (DPV), respectively. The results show that the MIP sensor has higher sensitivity than the bare GCE. Both were applied to commercial human serum samples and pharmaceutical dosage forms. The recovery studies were performed, and the recovery % and RSD% results are within the acceptable range. Therefore, the GCE and MIP sensors have good selectivity, accuracy and precision.
dc.description.sponsorshipSERB-International Research Experience (SIRE) fellowship [SIR/2022/001129]
dc.description.sponsorshipScientific and Technological Research Council of Trkiye (TUBITAK) [BIDEB/2221]
dc.description.sponsorshipAhmet Cetinkaya, thanks to his grant from the Scientific and Technological Research Council of Tuerkiye (TUBITAK) under the BIDEB/2218-National Postdoctoral Research Scholarship Program and ARDEB/1004-Center of Excellence Support Program (Project No: 20AG003) . Nimisha Jadon thanks the SERB (Science & Engineering Research Board) , New Delhi for providing the financial support underthe SERB-International Research Experience (SIRE) fellowship (Award No. SIR/2022/001129) for Year 2023-24. Batoul Hosseinzadeh thanks the financial support from the Scientific and Technological Research Council of Tuerkiye (TUBITAK) under the BIDEB/2221 Fellowships for Visiting Scientists and Scientists on Sabbatical Leave.r the SERB-International Research Experience (SIRE) fellowship (Award No. SIR/2022/001129) for Year 2023-24. Batoul Hosseinzadeh thanks the financial support from the Scientific and Technological Research Council of Turkiye (TUBITAK) under the BIDEB/2221 Fellowships for Visiting Scientists and Scientists on Sabbatical Leave.
dc.identifier.doi10.1016/j.electacta.2024.144823
dc.identifier.issn0013-4686
dc.identifier.issn1873-3859
dc.identifier.orcid0000-0002-4093-441X
dc.identifier.orcid0000-0003-0578-5399
dc.identifier.orcid0000-0001-5014-0907
dc.identifier.orcid0000-0001-7494-3077
dc.identifier.scopus2-s2.0-85201112594
dc.identifier.scopusqualityQ1
dc.identifier.urihttps://doi.org/10.1016/j.electacta.2024.144823
dc.identifier.urihttps://hdl.handle.net/20.500.14854/10989
dc.identifier.volume503
dc.identifier.wosWOS:001296941000001
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherPergamon-Elsevier Science Ltd
dc.relation.ispartofElectrochimica Acta
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20251020
dc.subjectRiociguat
dc.subjectMolecularly imprinted polymer
dc.subjectElectrochemical sensor
dc.subjectSensitivity
dc.subjectReal sample
dc.titleInvestigation of electrochemical behaviour and determination of Riociguat with bare GCE and molecularly imprinted polymer-based electrochemical sensor
dc.typeArticle

Dosyalar