Elektro-perokson hibrit prosesi ile fenol giderimi

dc.contributor.advisorHekimbaşı, Enis Bülent
dc.contributor.authorÖztürk, Funda Bahar
dc.date.accessioned2025-10-29T09:26:44Z
dc.date.issued2018
dc.departmentEnstitüler, Lisansüstü Eğitim Enstitüsü, Çevre Mühendisliği Ana Bilim Dalı
dc.description.abstractBu çalışmada, fenolün, yeni bir sistem olan Elektro-perokson (E-perokson) ile giderimi çalışılmıştır. Çalışmada, elektrooksidasyon, ozon ve E-perokson prosesleri olmak üzere, üç farklı prosesin fenol giderim konsantrasyonları karşılaştırılmıştır. İlk olarak fenolün giderimi üzerindeki etkisini anlamak üzere; akım, ozon dozu ve pH olarak, üç farklı parametre incelenmiştir. Yapılan deneyler sonucu optimum şartlar elde edilerek, bir sonraki aşamada proseslerin H2O2, OH• radikali ve ozon üretim kapasiteleri karşılaştırmalı olarak sunulmuştur. 0,1 A akım, 4 mg/L ozon dozu ve fenolün doğal pH 7,5 optimum şartlar olarak belirlenmiştir. Ozonlama ve E-perokson proseslerinde, ilk dakikalardan itibaren yüksek konsantrasyonda OH• radikal üretilirken, elektrooksidasyon prosesinde OH• radikal üretimi gerçekleşmemiştir. Elektrooksidasyon prosesinde fenol giderim hızı belirgin bir şekilde düşük iken, E-perokson prosesinde, fenolün tamamen giderimi sağlanmıştır. Fenol giderim oranı, ozonlama işleminde de yüksek miktarda meydana gelmiştir, fakat E-perokson prosesine göre daha yavaş gerçekleşmiştir. Fenol ve fenol yan ürünleri HPLC ile tespit edilmiştir.
dc.description.abstractIn this study, a new system which is an Electro-peroxone has been studied for removal of phenol. Belong the study, As three different processes, Electrooxidation, ozone and E-peroxone process were compared about phenol removal concentrations. Firstly, to understand the effect on phenol removal; as current, ozone dose and pH, three different parameters were investigated. Experiments were carried out to obtain optimum conditions, at the next stage in processes H2O2, OH• radical and ozone production capacities were presented comparatively. 0,1 A current, 4 mgL-1 ozone dose and natural pH of phenol pH 7,5 were identified as optimum conditions. In Ozonation and E-peroxone processes, at high concentration from the first minute, while OH• radical was producing, there was not exist OH• radical production in Electrooxidation process. While the rate of phenol removal in the EOX process was significantly lower, in E-peroxone process, phenol was completely removed. Phenol removal rate was very high in the ozonation process as E-peroxone process. In addition, according to E-peroxone process, ozonation process was slower related to phenol removal. In addition, phenol and its by-products were identified by HPLC.
dc.identifier.endpage70
dc.identifier.startpage1
dc.identifier.urihttps://tez.yok.gov.tr/UlusalTezMerkezi/TezGoster?key=fS4sqEZr79C_n60Rk6MjFbucmnbjWPqbhnb76noUBEo3cys8cOCyVvRjF4HYLcmG
dc.identifier.urihttps://hdl.handle.net/20.500.14854/1066
dc.identifier.yoktezid523422
dc.institutionauthorÖztürk, Funda Bahar
dc.language.isotr
dc.publisherGebze Teknik Üniversitesi, Lisansüstü Eğitim Enstitüsü
dc.relation.publicationcategoryTez
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_TEZ_20251020
dc.subjectÇevre Mühendisliği
dc.subjectEnvironmental Engineering
dc.titleElektro-perokson hibrit prosesi ile fenol giderimi
dc.title.alternativePhenol removal with electro-peroxone hybrid procedure
dc.typeMaster Thesis

Dosyalar