From Lab to Field: Damp Heat Testing and its Implications for PV Module Service Lifetime

dc.contributor.authorGök, Abdülkerim
dc.date.accessioned2025-10-29T11:34:07Z
dc.date.issued2025
dc.departmentFakülteler, Temel Bilimler Fakültesi, Matematik Bölümü
dc.departmentFakülteler, Mühendislik Fakültesi, Malzeme Bilimi ve Mühendisliği Bölümü
dc.description.abstractDamp heat testing, as outlined in the IEC 61215 standard, evaluates PV modules under prolonged humidity exposure. However, its effectiveness as a reliability test remains debated. This study maps damp heat testing times equivalent to a service lifetime of 30 years across Europe, highlighting the impact of local climate conditions. The activation energy of power degradation is key in determining testing times. For an activation energy of 0.6 eV, testing times range from over 2250 h in southern Europe to <750 h in northern Europe. In central Europe, testing times generally range from 1250 to 1750 h. Madrid and Rome stand out among major European capitals for their testing times, with Madrid having one of the shortest and Rome one of the longest. In Madrid, increasing the activation energy from 0.4 to 0.8 eV reduces the testing time from 5548 h to just 290 h. To ensure the standard testing time of 1000 h represents a service lifetime of 30 years across Europe, the activation energy should be at least 0.7 eV. These findings emphasize the need for customized testing protocols that consider regional climate differences and design factors, rather than relying on a one-size-fits-all approach.
dc.description.sponsorshipTrkiye Bilimsel ve Teknolojik Arascedil;tirma Kurumu [120N520]
dc.description.sponsorshipScientific and Technological Research Council of Turkey (TUBITAK)
dc.description.sponsorshipThis work was conducted as part of the PV40+ Solar-Era.NET project and supported by the funding from The Scientific and Technological Research Council of Turkey (TUBITAK) [grant number 120N520]. The author would like to acknowledge the help of Vahit A. Yenigul for the mapping procedure.
dc.identifier.doi10.1002/gch2.202400229
dc.identifier.issn2056-6646
dc.identifier.issue4
dc.identifier.pmid40255234
dc.identifier.scopus2-s2.0-105002655249
dc.identifier.scopusqualityQ1
dc.identifier.urihttps://doi.org/10.1002/gch2.202400229
dc.identifier.urihttps://hdl.handle.net/20.500.14854/12741
dc.identifier.volume9
dc.identifier.wosWOS:001451014400001
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.institutionauthorGok, Abdulkerim
dc.language.isoen
dc.publisherWiley-V C H Verlag Gmbh
dc.relation.ispartofGlobal Challenges
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WOS_20251020
dc.subjectdamp heat
dc.subjectdegradation
dc.subjectphotovoltaic modules
dc.subjectservice lifetime
dc.subjecttesting time
dc.titleFrom Lab to Field: Damp Heat Testing and its Implications for PV Module Service Lifetime
dc.typeArticle

Dosyalar