AHP-Based Decision for the Selection of a Draw Solution for Anaerobic Osmotic Membrane Bioreactors

dc.contributor.authorGuney, Ilknur Yalcin
dc.contributor.authorHasanoglu, Sumeyye
dc.contributor.authorYilmaz, Gulsum
dc.contributor.authorVergili, Ilda
dc.contributor.authorGonder, Zeren Beril
dc.contributor.authorAydiner, Coskun
dc.contributor.authorKaya, Yasemin
dc.date.accessioned2025-10-29T11:20:45Z
dc.date.issued2025
dc.departmentFakülteler, Mühendislik Fakültesi, Çevre Mühendisliği Bölümü
dc.description.abstractThe selection of a suitable draw solution (DS) is critically important for the forward osmosis (FO)-based processes since membrane fouling and inhibition caused by DS are the key problems in anaerobic osmotic membrane bioreactor (AnOMBR) systems. This study aims to select a suitable DS for the AnOMBR system treating slaughterhouse wastewater, considering the results of FO performance and the biochemical methane potential (BMP) test. In the first step of the study, the DSs obtained from the literature review were subjected to prescreening, and 18 DSs were evaluated. Eight out of 18 DSs (4 organics and 4 inorganics) were selected using the first analytical hierarchical process (AHP). In the second stage, reverse salt flux selectivity (RSFS), water flux (J w), and reverse salt flux (J s) values were determined to evaluate the FO performance of the 8 selected DSs by batch FO experiments. A BMP test was performed to investigate the inhibition effect of each DS on the anaerobic performance. The experimental results of batch FO and BMP studies were subjected to a second AHP analysis. The second AHP analysis showed that MgCl2 was the most suitable DS. The autopsy analysis demonstrated that the primary source of fouling on the FO membrane was the accumulation of MgCl2 on the membrane's surface. Although the fouling on the FO membrane did not seriously damage the membrane structure, it caused the membrane surface to become rougher and more hydrophobic.
dc.description.sponsorshipScientific and Technological Research Council of Turkey (TUBITAK) [119Y413]
dc.description.sponsorshipScientific Research Projects Coordination Unit of Istanbul University-Cerrahpasa [35022]
dc.description.sponsorshipThis study was funded by the Scientific and Technological Research Council of Turkey (TUBITAK) (Project Number: 119Y413) and the Scientific Research Projects Coordination Unit of Istanbul University-Cerrahpasa (Project Number: 35022).
dc.identifier.doi10.1021/acs.iecr.4c03941
dc.identifier.endpage1751
dc.identifier.issn0888-5885
dc.identifier.issn1520-5045
dc.identifier.issue3
dc.identifier.orcid0000-0002-1660-2423
dc.identifier.orcid0000-0002-0302-7765
dc.identifier.scopus2-s2.0-85214340698
dc.identifier.scopusqualityQ1
dc.identifier.startpage1741
dc.identifier.urihttps://doi.org/10.1021/acs.iecr.4c03941
dc.identifier.urihttps://hdl.handle.net/20.500.14854/8722
dc.identifier.volume64
dc.identifier.wosWOS:001393296900001
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherAmer Chemical Soc
dc.relation.ispartofIndustrial & Engineering Chemistry Research
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20251020
dc.subjectWaste-Water Treatment
dc.subjectThin-Film Composite
dc.subjectOsmosis Membranes
dc.subjectFertilizer-Drawn
dc.subjectPerformance
dc.subjectRecovery
dc.subjectMicrofiltration
dc.subjectOperation
dc.subjectDigestion
dc.subjectSalt
dc.titleAHP-Based Decision for the Selection of a Draw Solution for Anaerobic Osmotic Membrane Bioreactors
dc.typeArticle

Dosyalar