Effects of source voltage harmonic distortion on power factor compensation in triac controlled AC chopper circuits

dc.contributor.authorBalci, Murat Erhan
dc.contributor.authorHakan Hocaoglu, M. Hakan
dc.date.accessioned2025-10-29T12:10:31Z
dc.date.issued2005
dc.departmentGebze Teknik Üniversitesi
dc.descriptionSixth International Conference on Power Electronics and Drive Systems, PEDS 2005 -- Kualu Lumpur -- 69272
dc.description.abstractIn recent years, detailed modeling of power electronic devices and their behavior on different system conditions are a great concern of the power industries and customers. One of the widely proliferated such devices is the triac controlled ac choppers. Although these types of devices have important application areas, their poor power factor performance is the main obstacle for the large scale implementation in power systems. This paper presents an analysis on the behaviour of a single phase load composed with triac controlled ac chopper during reactive power compensation under nonsinusoidal voltage. The results of these analysis shows that for high conduction angle distortion on the source voltage improve the power factor which is contradicting with the previous findings. In addition, it is observed that, performance of power factor compensation systems are heavily affected by source voltage harmonics phase angles which are ignored in existing literature. © 2005 IEEE. © 2008 Elsevier B.V., All rights reserved.
dc.identifier.endpage1204
dc.identifier.isbn9780780392960
dc.identifier.isbn9781424441662
dc.identifier.isbn9781509023646
dc.identifier.isbn9781467317900
dc.identifier.isbn9781612849997
dc.identifier.isbn9781538664995
dc.identifier.isbn0780392965
dc.identifier.isbn9798350399967
dc.identifier.isbn0780378857
dc.identifier.isbn9781424406456
dc.identifier.issn2164-5264
dc.identifier.issn2164-5256
dc.identifier.scopus2-s2.0-33847335622
dc.identifier.scopusqualityN/A
dc.identifier.startpage1199
dc.identifier.urihttps://hdl.handle.net/20.500.14854/15208
dc.identifier.volume2
dc.indekslendigikaynakScopus
dc.language.isoen
dc.relation.ispartofProceedings of the International Conference on Power Electronics and Drive Systems
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_Scopus_20251020
dc.subjectAc chopper circuits
dc.subjectHarmonics
dc.subjectNonsinusoidal condition
dc.subjectPower factor
dc.subjectReactive power compensation
dc.titleEffects of source voltage harmonic distortion on power factor compensation in triac controlled AC chopper circuits
dc.typeConference Object

Dosyalar