Extraction of media and plaque boundaries in intravascular ultrasound images by level sets and min/max flow

dc.contributor.authorIskurt, Ali
dc.contributor.authorBecerikli, Yasar
dc.date.accessioned2025-10-29T11:13:42Z
dc.date.issued2010
dc.departmentGebze Teknik Üniversitesi
dc.description.abstractEstimation of the plaque area in intravascular ultrasound images after extraction of the media and plaque-lumen interfaces is an important application of computer-aided diagnosis in medical imaging. This paper presents a novel system for fully automatic and fast calculation of plaque quantity by capturing the surrounding ring called media. The system utilizes an algorithm that consists of an enhanced technique for noise removal and a method of detecting different iso levels by sinking the image gradually under zero level. Moreover, an important novelty with this technique is the simultaneous extraction of media and lumen-plaque interfaces at satisfactory levels. There are no higher dimensional surfaces and evolution of contours, stopping at high image gradients. Thus, the system runs really fast with curvature velocity only and has no complexity. Experiments also show that this shape-recovering curvature term not only removes the noisy behaviour of ultrasound images but also strengthens very weak boundaries and even completes the missing walls of the media. In addition, the lumen-plaque interface can be detected simultaneously. For validation, a new and very useful algorithm is developed for labelling of intravascular ultrasound images, taken from video sequences of 15 patients, and a comparison-based verification is done between manual contours by experts and the contours extracted by our system.
dc.identifier.doi10.1111/j.1468-0394.2010.00510.x
dc.identifier.endpage113
dc.identifier.issn0266-4720
dc.identifier.issue2
dc.identifier.orcid0000-0002-2951-7287
dc.identifier.scopus2-s2.0-77951790033
dc.identifier.scopusqualityQ1
dc.identifier.startpage101
dc.identifier.urihttps://doi.org/10.1111/j.1468-0394.2010.00510.x
dc.identifier.urihttps://hdl.handle.net/20.500.14854/6867
dc.identifier.volume27
dc.identifier.wosWOS:000277205200004
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherWiley-Blackwell
dc.relation.ispartofExpert Systems
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20251020
dc.subjectIVUS
dc.subjectmedia
dc.subjectsegmentation
dc.subjectmin/max flow
dc.subjectlevel sets
dc.subjectcomputer-aided diagnosis
dc.titleExtraction of media and plaque boundaries in intravascular ultrasound images by level sets and min/max flow
dc.typeArticle

Dosyalar