ZnO Nanosheets-Decorated ERGO Layers: An Efficient Electrochemical Sensor for Non-Enzymatic Uric Acid Detection
| dc.contributor.author | Eryigit, M. | |
| dc.contributor.author | Urhan, B. Kurt | |
| dc.contributor.author | Dogan, H. Ozturk | |
| dc.contributor.author | Ozer, T. Oznuluer | |
| dc.contributor.author | Demir, U. | |
| dc.date.accessioned | 2025-10-29T11:15:48Z | |
| dc.date.issued | 2022 | |
| dc.department | Fakülteler, Temel Bilimler Fakültesi, Kimya Bölümü | |
| dc.description.abstract | Electrochemically reduced graphene oxide/zinc oxide (ERGO/ZnO) nanocomposite was simultaneously co-electrodeposited based on a one-step electrodeposition approach at room temperature on an indium tin oxide (ITO) electrode from an aqueous solution without using specific reducing agents. The electrochemical fabricated ITO-ERGO/ZnO electrode was characterized using field emission scanning electron microscopy (FESEM), X-ray diffraction spectroscopy (XRD), X-ray photoelectron spectroscopy (XPS), Raman spectroscopy, and electrochemical impedance spectroscopy (EIS) techniques. The biosensor properties of the ITO-ERGO/ZnO electrodes were investigated in terms of their response toward uric acid (UA) sensing via enzyme-free amperometry. The linear current response for UA on the ITO-ERGO/ZnO electrode in the concentration range of 1-400 mu M with a sensitivity of 150.7 mu A cm(-2) mM(-1) was obtained. The main advantage of the ITO-ERGO/ZnO electrode was a relatively low detection limit for estimating UA, high selectivity, good repeatability, and long-term stability. In addition, the fabrication procedure of the designed biosensor was straightforward, practicable, and inexpensive. | |
| dc.description.sponsorship | Scientific and Technological Research Council of Turkey (TUB.ITAK) [112T791] | |
| dc.description.sponsorship | This work was supported by the Scientific and Technological Research Council of Turkey (TUB.ITAK) under Grant 112T791. | |
| dc.identifier.doi | 10.1109/JSEN.2022.3150088 | |
| dc.identifier.endpage | 5561 | |
| dc.identifier.issn | 1530-437X | |
| dc.identifier.issn | 1558-1748 | |
| dc.identifier.issue | 6 | |
| dc.identifier.orcid | 0000-0002-8742-6789 | |
| dc.identifier.orcid | 0000-0003-3208-9671 | |
| dc.identifier.orcid | 0000-0002-3123-8594 | |
| dc.identifier.orcid | 0000-0002-4072-7744 | |
| dc.identifier.scopus | 2-s2.0-85124739186 | |
| dc.identifier.scopusquality | Q1 | |
| dc.identifier.startpage | 5555 | |
| dc.identifier.uri | https://doi.org/10.1109/JSEN.2022.3150088 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14854/7245 | |
| dc.identifier.volume | 22 | |
| dc.identifier.wos | WOS:000770054800078 | |
| dc.identifier.wosquality | Q1 | |
| dc.indekslendigikaynak | Web of Science | |
| dc.indekslendigikaynak | Scopus | |
| dc.language.iso | en | |
| dc.publisher | IEEE-Inst Electrical Electronics Engineers Inc | |
| dc.relation.ispartof | IEEE Sensors Journal | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.snmz | KA_WOS_20251020 | |
| dc.subject | Electrodes | |
| dc.subject | Zinc oxide | |
| dc.subject | II-VI semiconductor materials | |
| dc.subject | Sensors | |
| dc.subject | Indium tin oxide | |
| dc.subject | Graphene | |
| dc.subject | Biosensors | |
| dc.subject | Co-electrodeposition | |
| dc.subject | electroreduced graphene oxide | |
| dc.subject | uric acid sensor | |
| dc.subject | ZnO nanosheets | |
| dc.title | ZnO Nanosheets-Decorated ERGO Layers: An Efficient Electrochemical Sensor for Non-Enzymatic Uric Acid Detection | |
| dc.type | Article |








