dc.description.abstractOrganic and inorganic polyelectrolytes are commonly used as coagulants or flocculants in membrane bioreactor to enhance the filtration properties of membranes. The main objective of this study was to determine the effectiveness of organic cationic polyelectrolyte (CPE) addition on filterability of various membranes and to investigate the influences on fouling of membranes. First, batch tests were performed to determine the optimum polyelectrolyte concentration at which the highest soluble microbial products (SMPs) removal was observed. Then, short-term filtration test were conducted. Cellulose acetate, polyethersulfone, mixed ester, polycarbonate (CA, PES, ME, PC) membranes with two different pore sizes (0.45-0.40 and 0.22-0.20 mu m) were used in submerged MBR experiments. Permeate flux decline at constant vacuum was observed with time. Protein and carbohydrate analysis were performed in the permeate samples. Filtration resistances were determined for each membrane. Cake resistance was observed to be the most significant fouling mechanism for all membranes. Polyelectrolyte addition decreased the cake resistance. The effect of polyelectrolyte on pore resistance was relatively insignificant. The results showed that addition of polyelectrolyte had significant impact on sustainable filtration time. (C) 2011 Elsevier By. All rights reserved.
dc.description.sponsorshipTUBITAK, the Scientific and Technological Research Council of Turkey [108Y129]
dc.description.sponsorshipThis study was financially supported by the TUBITAK, the Scientific and Technological Research Council of Turkey (Project No: 108Y129).
dc.identifier.doi10.1016/j.memsci.2011.04.048
dc.identifier.endpage181
dc.identifier.issn0376-7388
dc.identifier.issn1873-3123
dc.identifier.issue1-2
dc.identifier.orcid0000-0003-3023-4556
dc.identifier.orcid0000-0002-8406-0718
dc.identifier.scopus2-s2.0-79958076319
dc.identifier.scopusqualityQ1
dc.identifier.startpage175
dc.identifier.urihttps://doi.org/10.1016/j.memsci.2011.04.048
dc.identifier.urihttps://hdl.handle.net/20.500.14854/9942
dc.identifier.volume377
dc.identifier.wosWOS:000292580000017
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherElsevier
dc.relation.ispartofJournal of Membrane Science
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20251020
dc.subjectActivated sludge
dc.subjectMicrofiltration
dc.subjectSubmerged membrane bioreactor
dc.subjectFlux enhancing chemical
dc.subjectMembrane fouling
dc.subjectExtracellular polymeric substances (EPSs)
dc.subjectSoluble microbial products (SMPs)
dc.titleEffects of cationic polyelectrolyte on filterability and fouling reduction of submerged membrane bioreactor (MBR)
dc.typeArticle

Dosyalar