Influences of electroosmosis and electrophoresis on permeate flux and membrane fouling in submerged membrane bioreactors (SMBRs)
| dc.contributor.author | Bayar, Secil | |
| dc.contributor.author | Karagündüz, Ahmet | |
| dc.contributor.author | Keskinler, Bülent | |
| dc.date.accessioned | 2025-10-29T11:09:46Z | |
| dc.date.issued | 2016 | |
| dc.department | Fakülteler, Mühendislik Fakültesi, Çevre Mühendisliği Bölümü | |
| dc.description.abstract | The objective of this study was to investigate the influences of electroosmosis (EO) and electrophoresis (EP) on the permeate flux in submerged membrane bioreactors. When a polymeric membrane is placed in between an anode and a cathode, both EO and EP occur simultaneously, causing enhancement in flux. Results showed that after 150 min of filtration, the permeate fluxes were 60, 115, 175 and 260 L/m(2)/h at 0, 30, 40 and 50 V, respectively. It was shown that the EO was linearly changing with increasing voltage, reaching up to 54 L/m(2)/h at 50 V. EP was found to be a significant process in removing soluble microbial products from the membrane surface, resulting in an increase in permeate flux as the filtration progressed. About 20-fold of smaller protein and carbohydrate concentrations were found in the cake layer when the electrical field (EF) was applied. However, the EF application promoted pore fouling, because of the calcium and magnesium scaling. | |
| dc.description.sponsorship | TUBITAK, the Scientific and Technological Research Council of Turkey [110Y254] | |
| dc.description.sponsorship | This study was financially supported by the TUBITAK, the Scientific and Technological Research Council of Turkey (Project No. 110Y254). The authors are very grateful to MEM-TEK for conducting streaming potential measurements. | |
| dc.identifier.doi | 10.2166/wst.2016.280 | |
| dc.identifier.endpage | 776 | |
| dc.identifier.issn | 0273-1223 | |
| dc.identifier.issn | 1996-9732 | |
| dc.identifier.issue | 3 | |
| dc.identifier.orcid | 0000-0002-8406-0718 | |
| dc.identifier.pmid | 27508382 | |
| dc.identifier.scopus | 2-s2.0-84982292068 | |
| dc.identifier.scopusquality | Q2 | |
| dc.identifier.startpage | 766 | |
| dc.identifier.uri | https://doi.org/10.2166/wst.2016.280 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14854/5964 | |
| dc.identifier.volume | 74 | |
| dc.identifier.wos | WOS:000382252700023 | |
| dc.identifier.wosquality | Q3 | |
| dc.indekslendigikaynak | Web of Science | |
| dc.indekslendigikaynak | Scopus | |
| dc.indekslendigikaynak | PubMed | |
| dc.language.iso | en | |
| dc.publisher | Iwa Publishing | |
| dc.relation.ispartof | Water Science and Technology | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.snmz | KA_WOS_20251020 | |
| dc.subject | electrofiltration | |
| dc.subject | electroosmosis | |
| dc.subject | electrophoresis | |
| dc.subject | membrane bioreactor | |
| dc.title | Influences of electroosmosis and electrophoresis on permeate flux and membrane fouling in submerged membrane bioreactors (SMBRs) | |
| dc.type | Article |