Application of Six Sigma methodology to a diagnostic imaging process

dc.contributor.authorTaner, Mehmet Tolga
dc.contributor.authorSezen, Bülent
dc.contributor.authorAtwat, Kamal M.
dc.date.accessioned2025-10-29T11:16:11Z
dc.date.issued2012
dc.departmentFakülteler, İşletme Fakültesi, İşletme Bölümü
dc.description.abstractPurpose - This paper aims to apply the Six Sigma methodology to improve workflow by eliminating the causes of failure in the medical imaging department of a private Turkish hospital. Design/methodology/approach - Implementation of the design, measure, analyse, improve and control (DMAIC) improvement cycle, workflow chart, fishbone diagrams and Pareto charts were employed, together with rigorous data collection in the department. The identification of root causes of repeat sessions and delays was followed by failure, mode and effect analysis, hazard analysis and decision tree analysis. Findings - The most frequent causes of failure were malfunction of the RIS/PACS system and improper positioning of patients. Subsequent to extensive training of professionals, the sigma level was increased from 3.5 to 4.2. Research limitations/implications - The data were collected over only four months. Practical implications - Six Sigma's data measurement and process improvement methodology is the impetus for health care organisations to rethink their workflow and reduce malpractice. It involves measuring, recording and reporting data on a regular basis. This enables the administration to monitor workflow continuously. Social implications - The improvements in the workflow under study, made by determining the failures and potential risks associated with radiologic care, will have a positive impact on society in terms of patient safety. Having eliminated repeat examinations, the risk of being exposed to more radiation was also minimised. Originality/value - This paper supports the need to apply Six Sigma and present an evaluation of the process in an imaging department.
dc.identifier.doi10.1108/09526861211221482
dc.identifier.endpage+
dc.identifier.issn0952-6862
dc.identifier.issn1758-6542
dc.identifier.issue4
dc.identifier.orcid0000-0001-5857-9754
dc.identifier.pmid22755481
dc.identifier.scopus2-s2.0-84860358712
dc.identifier.scopusqualityQ2
dc.identifier.startpage274
dc.identifier.urihttps://doi.org/10.1108/09526861211221482
dc.identifier.urihttps://hdl.handle.net/20.500.14854/7445
dc.identifier.volume25
dc.identifier.wosWOS:000212564700019
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherEmerald Group Publishing Ltd
dc.relation.ispartofInternational Journal of Health Care Quality Assurance
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20251020
dc.subjectSix Sigma
dc.subjectRadiology
dc.subjectImage
dc.subjectRepeats
dc.subjectCost
dc.subjectHealth services
dc.subjectQuality improvement
dc.subjectTurkey
dc.subjectMedical diagnosis
dc.subjectImage scanners
dc.titleApplication of Six Sigma methodology to a diagnostic imaging process
dc.typeArticle