Sorption of Ni(II) ions from aqueous solution by Lewatit cation-exchange resin

dc.contributor.authorDizge, Nadir
dc.contributor.authorKeskinler, Buelent
dc.contributor.authorBarlas, Hulusi
dc.date.accessioned2025-10-29T11:26:40Z
dc.date.issued2009
dc.departmentFakülteler, Mühendislik Fakültesi, Çevre Mühendisliği Bölümü
dc.description.abstractIon-exchange is an alternative process for uptake of heavy metals from aqueous solutions. In the present study, the sorption of nickel(II) ions from aqueous solution was investigated by using Lewatit MonoPlus SP 112 (strongly acidic, macroporous cation-exchange resin) in a batch adsorption system as a function of pH (2.0-8.0), initial nickel concentration (50-200 mg/L), resin dosage (0.5-2.0 g/L), contact time (0.5-3h), and temperatures (298-318K). The data were analyzed on the basis of Lagergren pseudo-first order, pseudo-second order (Types 1-5), Elovich and external, Weber-Morris intraparticle, pore-surface mass diffusion models. The experimental data showed that the maximum pH for efficient sorption of nickel(II) was 6.0. At the optimal conditions, nickel(II) ions sorption on the resin was decreased when the initial metal concentration increased. The results indicated that the resin dosage strongly affected the amount of nickel(H) ions removed from aqueous solution. The adsorption process was very fast due to 80% of nickel(II) sorption was occurred within 30 min and equilibrium was reached at about 90 min, Freundlich and Langmuir adsorption isotherm models were used for sorption equilibrium data and the maximum adsorption capacity (171 mg/g) of Lewatit MonoPlus SP 112 was obtained from Langmuir isotherm. The thermodynamic parameters (Delta G degrees, free energy change; Delta S degrees, enthalpy change; and Delta H degrees, entropy change) for sorption of nickel(II) ions were evaluated. The rise in temperature caused a partly increase in the value of the equilibrium constant (K-c) for the sorption of nickel(II) ions. Moreover, column flow adsorption study was also studied. Breakthrough curves were obtained from column flow studies by using both synthetic solution and rinsing bath water of filter industry. The column regeneration was carried out for two sorption-desorption cycles. The eluant used for regeneration of the cation-exchange resin was 7% (w/w) HCl. The experimental results demonstrated that Lewatit MonoPlus SP 112 cation-exchange resin could be used effectively for the removal of nickel(II) ions from aqueous medium. (C) 2009 Elsevier B.V. All rights reserved.
dc.identifier.doi10.1016/j.jhazmat.2009.01.073
dc.identifier.endpage926
dc.identifier.issn0304-3894
dc.identifier.issn1873-3336
dc.identifier.issue1-3
dc.identifier.pmid19231079
dc.identifier.scopus2-s2.0-67649249518
dc.identifier.scopusqualityQ1
dc.identifier.startpage915
dc.identifier.urihttps://doi.org/10.1016/j.jhazmat.2009.01.073
dc.identifier.urihttps://hdl.handle.net/20.500.14854/10373
dc.identifier.volume167
dc.identifier.wosWOS:000267267000133
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherElsevier Science Bv
dc.relation.ispartofJournal of Hazardous Materials
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20251020
dc.subjectIon exchange
dc.subjectCation-exchange resin
dc.subjectLewatit MonoPlus SP 112
dc.subjectNickel
dc.subjectEquilibrium
dc.titleSorption of Ni(II) ions from aqueous solution by Lewatit cation-exchange resin
dc.typeArticle

Dosyalar