Poly(glycidyl methacrylate-co-3-thienylmethylmethacrylate) as an immobilization matrix for microbial glycerol biosensing based on Gluconobacter oxydans

dc.contributor.authorErgon-Can, Tulay
dc.contributor.authorErhan, Elif
dc.contributor.authorAlgur, Omer Faruk
dc.date.accessioned2025-10-29T11:24:07Z
dc.date.issued2015
dc.departmentFakülteler, Mühendislik Fakültesi, Çevre Mühendisliği Bölümü
dc.description.abstractA commercial strain of Gluconobacter oxydans together with a new co-polymer Poly(glycidyl methacrylate-co-3thienylmethylmethacrylate) (Poly(GMA-co-MTM)), which provides effective immobilization in the continuous flow system, was used in the sensor design. By taking the advantages of the nano-technology, carbon nanotubes (CNTs) were also added to the cell film and the sensitivity of the sensor was increased about 15 times. During the glycerol analysis in the continuous system, it was shown that composite film was not removed from the electrode surface and film elements were not washed out from the system. Glycerol analyses were performed by using batch loaded continuously flow cell at different flow rates of 1, 2, 4, and 6 mL/min. The linear range was found as 2-100 mM with the detection limit (LOD) of 0.057 mM according to S/N = 3. The calibration graphs were obtained for Poly(GMA-co-MTM)/G. oxydans and Poly(GMA-co-MTM)/CNT/G. oxydans biofilm electrodes in FIA mode, and sensitivities were found to be 1.50 nA/mM and 19.13 nA/mM, respectively. In this study, Poly(GMA-co-MTM) was used for the first time as a microbial matrix and was shown to be an effective immobilizatipn agent (C) 2015 Elsevier B.V. All rights reserved.
dc.identifier.doi10.1016/j.msec.2015.07.006
dc.identifier.endpage437
dc.identifier.issn0928-4931
dc.identifier.issn1873-0191
dc.identifier.orcid0000-0002-7553-7836
dc.identifier.pmid26249611
dc.identifier.scopus2-s2.0-84937035529
dc.identifier.scopusqualityN/A
dc.identifier.startpage432
dc.identifier.urihttps://doi.org/10.1016/j.msec.2015.07.006
dc.identifier.urihttps://hdl.handle.net/20.500.14854/9775
dc.identifier.volume56
dc.identifier.wosWOS:000359873900053
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherElsevier Science Bv
dc.relation.ispartofMaterials Science & Engineering C-Materials For Biological Applications
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20251020
dc.subjectCarbon nanotube
dc.subjectFlow injection analysis
dc.subjectGluconobacter oxydans
dc.subjectGlycerol
dc.subjectMicrobial biosensor
dc.subjectPoly(GMA-co-MTM)
dc.titlePoly(glycidyl methacrylate-co-3-thienylmethylmethacrylate) as an immobilization matrix for microbial glycerol biosensing based on Gluconobacter oxydans
dc.typeArticle

Dosyalar