Lab-on-a-chip based biosensor for the real-time detection of aflatoxin

dc.contributor.authorUludag, Yildiz
dc.contributor.authorEsen, Elif
dc.contributor.authorKokturk, Guzin
dc.contributor.authorOzer, Hayrettin
dc.contributor.authorMuhammad, Turghun
dc.contributor.authorOlcer, Zehra
dc.contributor.authorBasegmez, H. Imge Oktay
dc.date.accessioned2025-10-29T11:21:23Z
dc.date.issued2016
dc.departmentFakülteler, Temel Bilimler Fakültesi, Kimya Bölümü
dc.description.abstractPolymers were synthesized and utilized for aflatoxin detection coupled with a novel lab-on-a-chip biosensor: MiSens and high performance liquid chromatography (HPLC). Non-imprinted polymers (NIPs) were preferred to be designed and used due to the toxic nature of aflatoxin template and also to avoid difficult clean-up protocols. Towards an innovative miniaturized automated system, a novel biochip has been designed that consists of 6 working electrodes (1 mm diameter) with shared reference and counter electrodes. The aflatoxin detection has been achieved by a competition immunoassay that has been performed using the new biochips and the automated MiSens electrochemical biosensor device. For the assay, aflatoxin antibody has been captured on the Protein A immobilized electrode. Subsequently the sample and the enzyme-aflatoxin conjugate mixture has been injected to the electrode surfaces. The final injection of the enzyme substrate results in an amperometric signal. The sensor assays for aflatoxin B1 (AFB1) in different matrices were also performed using enzyme link immunosorbent assay (ELISA) and HPLC for confirmation. High recovery was successfully achieved in spiked wheat samples using NIP coupled HPLC and NIP coupled MiSens biosensor [2 ppb of aflatoxin was determined as 1.86 ppb (93% recovery), 1.73 ppb (86.5% recovery), 1.96 ppb (98% recovery) and 1.88 ppb (94.0% recovery) for immunoaffinity column (IAC)-HPLC, NIP-HPLC, Supel (TM) Tox SPE Cartridges (SUP)-HPLC and NIP-MiSens, respectively]. Aflatoxin detection in fig samples were also investigated with MiSens biosensor and the results were compared with HPLC method. The new biosensor allows real-time and on-site detection of AFB1 in foods with a rapid, sensitive, fully automated and miniaturized system and expected to have an immense economic impact for food industry. (C) 2016 Elsevier B.V. All rights reserved.
dc.description.sponsorshipBILGEM - TUBITAK (The Scientific and Technological Research Council of Turkey) [100121]
dc.description.sponsorshipRepublic of Turkey Ministry of Development Infra-structure Grant [2011K120020]
dc.description.sponsorshipTUBITAK BIDEB [2221]
dc.description.sponsorshipThe project is supported by BILGEM - TUBITAK (The Scientific and Technological Research Council of Turkey) (Grant no: 100121), the Republic of Turkey Ministry of Development Infra-structure Grant (No: 2011K120020) and TUBITAK BIDEB 2221. We gratefully acknowledge the BILGEM - Bioelectronics Devices and System Development Group for their contribution to the fabrication of the electrode arrays and sensor cassette. We are also thankful to Meltem Ucak (Yildiz Technical University) for her high performance during the internship.
dc.identifier.doi10.1016/j.talanta.2016.07.060
dc.identifier.endpage388
dc.identifier.issn0039-9140
dc.identifier.issn1873-3573
dc.identifier.orcid0000-0001-5562-9365
dc.identifier.pmid27591628
dc.identifier.scopus2-s2.0-84989313948
dc.identifier.scopusqualityQ1
dc.identifier.startpage381
dc.identifier.urihttps://doi.org/10.1016/j.talanta.2016.07.060
dc.identifier.urihttps://hdl.handle.net/20.500.14854/9021
dc.identifier.volume160
dc.identifier.wosWOS:000383524400049
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherElsevier Science Bv
dc.relation.ispartofTalanta
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20251020
dc.subjectAflatoxin
dc.subjectReal-time electrochemical profiling
dc.subjectAmperometry
dc.subjectMiSens biosensor
dc.subjectELISA
dc.subjectHPLC
dc.titleLab-on-a-chip based biosensor for the real-time detection of aflatoxin
dc.typeArticle

Dosyalar