Investigation of reusability of effluents from an organized industrial zone wastewater treatment plant using a pressure-driven membrane process

dc.contributor.authorOcal, Zehra Betul
dc.contributor.authorKaragündüz, Ahmet
dc.contributor.authorKeskinler, Bülent
dc.contributor.authorDizge, Nadir
dc.contributor.authorAshqar, Huthaifa I.
dc.date.accessioned2025-10-29T11:09:46Z
dc.date.issued2023
dc.departmentFakülteler, Mühendislik Fakültesi, Çevre Mühendisliği Bölümü
dc.description.abstractThe quantity of wastewater being discharged into the environment due to the rise in industrial activities is progressively growing over time. Aside from large environmental risk posed by untreated wastewater discharge, the reuse of treated water prevents wastage of large amount of water. For this reason, in this study, the reuse potential of an organized industrial zone wastewater was investigated by membrane processes. The appropriate membrane type and rejection performance were determined for various pollutant parameters including, conductivity, chemical oxygen demand (COD), total nitrogen (TN), chloride, and sulfate. Laboratory-scale batch membrane filtration experiments were performed by using three different membrane types (BW30, XLE, and X20). The experiments were conducted at 15 and 20 bar pressures and flux data were collected during the operations. The results showed that BW30 and X20 membranes could be operated comfortably with 80% recovery for the wastewater containing low and high sulfate concentrations. For the wastewater with low sulfate concentration, the fluxes of BW30 and X20 at 20 bar were 19.7 and 16.4 L/m(2)/h, respectively, at 80% recovery. On the other hand, for the wastewater with higher sulfate concentration, the fluxes of BW30 and X20 at 20 bar were 8.6 and 11.5 L/m2/h, respectively.
dc.identifier.doi10.2166/wrd.2023.066
dc.identifier.endpage570
dc.identifier.issn2709-6092
dc.identifier.issn2709-6106
dc.identifier.issue4
dc.identifier.orcid0000-0002-6835-8338
dc.identifier.orcid0000-0002-3617-5596
dc.identifier.scopus2-s2.0-85181527284
dc.identifier.scopusqualityQ1
dc.identifier.startpage559
dc.identifier.urihttps://doi.org/10.2166/wrd.2023.066
dc.identifier.urihttps://hdl.handle.net/20.500.14854/5978
dc.identifier.volume13
dc.identifier.wosWOS:001083397800001
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherIwa Publishing
dc.relation.ispartofWater Reuse
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WOS_20251020
dc.subjectmembrane
dc.subjectmembrane fouling
dc.subjectwater recovery
dc.subjectwater reuse
dc.titleInvestigation of reusability of effluents from an organized industrial zone wastewater treatment plant using a pressure-driven membrane process
dc.typeArticle

Dosyalar