The Influence of Operating Temperature on the Performance of BIPV Modules

dc.contributor.authorGök, Abdülkerim
dc.contributor.authorOzkalay, Ebrar
dc.contributor.authorFriesen, Gabi
dc.contributor.authorFrontini, Francesco
dc.date.accessioned2025-10-29T11:15:48Z
dc.date.issued2020
dc.departmentFakülteler, Temel Bilimler Fakültesi, Matematik Bölümü
dc.departmentFakülteler, Mühendislik Fakültesi, Malzeme Bilimi ve Mühendisliği Bölümü
dc.description.abstractTo investigate the effect of the operating temperature on the performance of building integrated photovoltaic modules, two different crystalline silicon (c-Si) module types (glass/backsheet and glass/glass) with two different mounting configurations (ventilated and insulated) were installed in Canobbio, Switzerland and monitored over more than four years outdoors. The differences in the performance loss rates (PLRs) between module types and mounting configurations were determined by using the year-over-year methodology. The glass/backsheet module was markedly affected by the higher operating temperature: PLR changed from 0.01%/yr for ventilated to -0.42%/yr for insulated. However, the glass/glass module showed an opposite and unexpected trend: PLR changed from -0.10%/yr for ventilated to 0.26%/yr for insulated. Analysis of the IV curve parameters revealed that the decreased performance of the insulated glass/backsheet module was chiefly due to the loss in the fill factor with increased resistance; however, the gain in the short-circuit current (I-sc) was the main driver for the increased performance of the insulated glass/glass module. Real-world temperature coefficients were further examined and they were mostly found to be in line with the values measured indoors. Lower power-temperature and higher current-temperature dependence of the insulated glass/glass module, compared to the ventilated construction, supported the observed performance and current behavior of this module.
dc.description.sponsorshipSwiss National Science Foundation under COST [IZCOZ0_182967/1]
dc.description.sponsorshipCOST Action PEARL PV Project for the Short-Term Scientific Mission at the University of Applied Sciences and Arts of Southern Switzerland (SUPSI) [CA 61235]
dc.description.sponsorshipSwiss National Science Foundation (SNF) [IZCOZ0_182967] Funding Source: Swiss National Science Foundation (SNF)
dc.description.sponsorshipThisworkwas supported by the Swiss National Science Foundation under COST IZCOZ0_182967/1. The work of Abdulkerim Gok was supported by a Grant from the COST Action PEARL PV Project (CA 61235Performance and Reliability of Photovoltaic Systems: Evaluations of LargeScale Monitoring Data) for the Short-Term Scientific Mission at the University of Applied Sciences and Arts of Southern Switzerland (SUPSI).
dc.identifier.doi10.1109/JPHOTOV.2020.3001181
dc.identifier.endpage1378
dc.identifier.issn2156-3381
dc.identifier.issn2156-3403
dc.identifier.issue5
dc.identifier.orcid0000-0003-0119-9261
dc.identifier.orcid0000-0002-3827-5259
dc.identifier.orcid0000-0003-3433-7106
dc.identifier.orcid0000-0002-6554-8937
dc.identifier.scopus2-s2.0-85091007327
dc.identifier.scopusqualityQ1
dc.identifier.startpage1371
dc.identifier.urihttps://doi.org/10.1109/JPHOTOV.2020.3001181
dc.identifier.urihttps://hdl.handle.net/20.500.14854/7250
dc.identifier.volume10
dc.identifier.wosWOS:000562057700023
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherIEEE-Inst Electrical Electronics Engineers Inc
dc.relation.ispartofIEEE Journal of Photovoltaics
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20251020
dc.subjectBuilding integrated photovoltaics (BIPV)
dc.subjectdegradation
dc.subjectoperating temperature
dc.subjectperformance loss rate (PLR)
dc.subjectreal-world temperature coefficients (TCOs)
dc.subjectthermal insulation
dc.subjectyear-over-year (YoY)
dc.titleThe Influence of Operating Temperature on the Performance of BIPV Modules