Anatomy of the organic carbon in an industrial wastewater: Implications of particle size distribution, respirometry and process modelling
| dc.contributor.author | Dogruel, Serdar | |
| dc.contributor.author | Altun, Atalay | |
| dc.contributor.author | Cokgor, Emine Ubay | |
| dc.contributor.author | Insel, Guclu | |
| dc.contributor.author | Keskinler, Bülent | |
| dc.contributor.author | Orhon, Derin | |
| dc.date.accessioned | 2025-10-29T11:23:29Z | |
| dc.date.issued | 2021 | |
| dc.department | Fakülteler, Mühendislik Fakültesi, Çevre Mühendisliği Bölümü | |
| dc.description.abstract | This study evaluated the fate of chemical oxygen demand (COD) fractions of an organized industrial district effluent treated with pilot membrane bioreactor (MBR) system. A series of respirometric analyses were performed on raw wastewater together with 450 nm, 100 kDa and 1 kDa filtered samples obtained from particle size distribution (PSD) experiments. The PSD analysis revealed that more than 300 mg/L of the influent COD accumulated in the lowest size range (<2 nm), accounting for 49-52 % of the total COD. The bulk (64 %) of the influent COD consisted of soluble hydrolysable COD (S-H1). The hydrolysis rates for S-H1 (0.80-1.28 1/day) were slightly below the levels suggested for domestic wastewaters, indicating the presence of inhibitory compounds in industrial wastewaters. The COD removal efficiency of MBR pilot was found as 85 %; however, 43 % of effluent COD (106 mg/L) still included rapidly hydrolysable organics in the size bracket of 5-30 nm. In this respect, the COD fractions for activated sludge process models used for MBR applications require a new-insight to correctly reflect organic matter balances in the treatment system. (C) 2020 Institution of Chemical Engineers. Published by Elsevier B.V. All rights reserved. | |
| dc.description.sponsorship | BYR Chemical Ltd. | |
| dc.description.sponsorship | Demirtas Organized Industrial District is kindly acknowledged for conducting the effluent analyses of MBR plant and sharing the operational data of full-scale wastewater treatment plant. This project is financially supported by BYR Chemical Ltd. | |
| dc.identifier.doi | 10.1016/j.psep.2020.09.002 | |
| dc.identifier.endpage | 266 | |
| dc.identifier.issn | 0957-5820 | |
| dc.identifier.issn | 1744-3598 | |
| dc.identifier.orcid | 0000-0001-6597-2693 | |
| dc.identifier.orcid | 0000-0003-4214-8436 | |
| dc.identifier.scopus | 2-s2.0-85090567848 | |
| dc.identifier.scopusquality | Q1 | |
| dc.identifier.startpage | 257 | |
| dc.identifier.uri | https://doi.org/10.1016/j.psep.2020.09.002 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14854/9476 | |
| dc.identifier.volume | 146 | |
| dc.identifier.wos | WOS:000613226900021 | |
| dc.identifier.wosquality | Q1 | |
| dc.indekslendigikaynak | Web of Science | |
| dc.indekslendigikaynak | Scopus | |
| dc.language.iso | en | |
| dc.publisher | Elsevier | |
| dc.relation.ispartof | Process Safety and Environmental Protection | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.snmz | KA_WOS_20251020 | |
| dc.subject | COD fractionation | |
| dc.subject | Hydrolysable COD | |
| dc.subject | Membrane bioreactor | |
| dc.subject | Organized industrial district | |
| dc.subject | Particle size distribution | |
| dc.subject | Textile wastewater | |
| dc.title | Anatomy of the organic carbon in an industrial wastewater: Implications of particle size distribution, respirometry and process modelling | |
| dc.type | Article |