Anatomy of the organic carbon in an industrial wastewater: Implications of particle size distribution, respirometry and process modelling

dc.contributor.authorDogruel, Serdar
dc.contributor.authorAltun, Atalay
dc.contributor.authorCokgor, Emine Ubay
dc.contributor.authorInsel, Guclu
dc.contributor.authorKeskinler, Bülent
dc.contributor.authorOrhon, Derin
dc.date.accessioned2025-10-29T11:23:29Z
dc.date.issued2021
dc.departmentFakülteler, Mühendislik Fakültesi, Çevre Mühendisliği Bölümü
dc.description.abstractThis study evaluated the fate of chemical oxygen demand (COD) fractions of an organized industrial district effluent treated with pilot membrane bioreactor (MBR) system. A series of respirometric analyses were performed on raw wastewater together with 450 nm, 100 kDa and 1 kDa filtered samples obtained from particle size distribution (PSD) experiments. The PSD analysis revealed that more than 300 mg/L of the influent COD accumulated in the lowest size range (<2 nm), accounting for 49-52 % of the total COD. The bulk (64 %) of the influent COD consisted of soluble hydrolysable COD (S-H1). The hydrolysis rates for S-H1 (0.80-1.28 1/day) were slightly below the levels suggested for domestic wastewaters, indicating the presence of inhibitory compounds in industrial wastewaters. The COD removal efficiency of MBR pilot was found as 85 %; however, 43 % of effluent COD (106 mg/L) still included rapidly hydrolysable organics in the size bracket of 5-30 nm. In this respect, the COD fractions for activated sludge process models used for MBR applications require a new-insight to correctly reflect organic matter balances in the treatment system. (C) 2020 Institution of Chemical Engineers. Published by Elsevier B.V. All rights reserved.
dc.description.sponsorshipBYR Chemical Ltd.
dc.description.sponsorshipDemirtas Organized Industrial District is kindly acknowledged for conducting the effluent analyses of MBR plant and sharing the operational data of full-scale wastewater treatment plant. This project is financially supported by BYR Chemical Ltd.
dc.identifier.doi10.1016/j.psep.2020.09.002
dc.identifier.endpage266
dc.identifier.issn0957-5820
dc.identifier.issn1744-3598
dc.identifier.orcid0000-0001-6597-2693
dc.identifier.orcid0000-0003-4214-8436
dc.identifier.scopus2-s2.0-85090567848
dc.identifier.scopusqualityQ1
dc.identifier.startpage257
dc.identifier.urihttps://doi.org/10.1016/j.psep.2020.09.002
dc.identifier.urihttps://hdl.handle.net/20.500.14854/9476
dc.identifier.volume146
dc.identifier.wosWOS:000613226900021
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherElsevier
dc.relation.ispartofProcess Safety and Environmental Protection
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20251020
dc.subjectCOD fractionation
dc.subjectHydrolysable COD
dc.subjectMembrane bioreactor
dc.subjectOrganized industrial district
dc.subjectParticle size distribution
dc.subjectTextile wastewater
dc.titleAnatomy of the organic carbon in an industrial wastewater: Implications of particle size distribution, respirometry and process modelling
dc.typeArticle

Dosyalar