Treatment of domestic wastewater phosphate by electrocoagulation using Fe and Al electrodes: A comparative study

dc.contributor.authorOmwene, P. I.
dc.contributor.authorKobya, M.
dc.date.accessioned2025-10-29T11:23:29Z
dc.date.issued2018
dc.departmentFakülteler, Mühendislik Fakültesi, Çevre Mühendisliği Bölümü
dc.description.abstractIn this work, phosphorus removal from domestic wastewater was studied through electrocoagulation (EC) using iron (Fe) and aluminium (Al) anodes in a batch EC reactor. Key parameters investigated include; initial pH, initial phosphorus concentration (C-i), reaction time, current density (j), metal-to-phosphorous ratio, charge loading (q) and electrode type. The Al/P mole ratio at current densities of 10, 20, 30 and 40 A/m(2) was obtained as 0.84, 1.68, 0.95 and 0.77, respectively, while the Fe/P mole ratio for these current densities was calculated as 1.81, 3.29, 4.09 and 4.48, respectively. The optimums to obtain <0.01 mg/L effluent P concentration at C-i = 52 mg/L PO4-P were; pH(i) = 4, j = 20 A/m(2) and EC time = 100 min (q = 954C) for Fe electrode, whereas for Al electrode, the optimums were; EC time = 50 min (q = 372C), pH(i) = 4, j = 20 A/m(2). Also, the final pHf increased with increase in EC time; when pH(i) = 4, C-i = 52 mg/L and j = 20 A/m(2), the final pH(f) was 8.52 at 50 min for Al electrode and 10.62 at 100 min for Fe electrode. The operating costs, energy and electrode consumptions were calculated as 1.032 $/m(3), 1.143 kWh/m(3) and 0.218 kg/m(3) respectively for Al electrode and 1.343 $/m(3), 4.179 kWh/m(3) and 0.884 kg/m(3), respectively for Fe electrodes. Overall, Al anodes provided a higher phosphorus removal efficiency in a shorter EC time and lesser metal-to-phosphorous ratio compared to Fe anodes. (C) 2018 Institution of Chemical Engineers. Published by Elsevier B.V. All rights reserved.
dc.identifier.doi10.1016/j.psep.2018.01.005
dc.identifier.endpage51
dc.identifier.issn0957-5820
dc.identifier.issn1744-3598
dc.identifier.orcid0000-0002-8513-677X
dc.identifier.scopus2-s2.0-85041378223
dc.identifier.scopusqualityQ1
dc.identifier.startpage34
dc.identifier.urihttps://doi.org/10.1016/j.psep.2018.01.005
dc.identifier.urihttps://hdl.handle.net/20.500.14854/9478
dc.identifier.volume116
dc.identifier.wosWOS:000435056700004
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherInst Chemical Engineers
dc.relation.ispartofProcess Safety and Environmental Protection
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20251020
dc.subjectPhosphorus removal
dc.subjectElectrocoagulation
dc.subjectDomestic wastewater
dc.subjectAl and Fe electrodes
dc.titleTreatment of domestic wastewater phosphate by electrocoagulation using Fe and Al electrodes: A comparative study
dc.typeArticle

Dosyalar