Preparation of Fe@Fe2O3/3D graphene composite cathode for electrochemical removal of sulfasalazine

dc.contributor.authorAmali, Somayeh
dc.contributor.authorZarei, Mahmoud
dc.contributor.authorEbratkhahan, Masoud
dc.contributor.authorKhataee, Alireza
dc.date.accessioned2025-10-29T11:29:51Z
dc.date.issued2021
dc.departmentFakülteler, Mühendislik Fakültesi, Çevre Mühendisliği Bölümü
dc.description.abstractIn the present study, heterogeneous electro-Fenton (EF) process was applied to remove the sulfasalazine (SU) pharmaceutical from aqueous solutions. In the first part, 3D graphene loaded with Fe@Fe2O3 core-shell nanowires (Fe@Fe2O3/3D-GO) was used as a cathode electrode in the EF process. Graphene oxide (GO) was synthesized for the synthesis of 3D graphene nanocomposites using the improved Hummers' method and subsequently 3D graphene synthesized by the hydrothermal method using glycine. Finally, Fe@Fe2O3/3D-GO composite was synthesized and its properties were assessed by Scanning electron microscopy, Atomic force microscopy, Brunauer-Emmett-Teller, Fourier-transform infrared spectroscopy and X-ray diffraction methods. Then, the cathode electrode was prepared using the resulting composite and its performance was evaluated using Cyclic Voltammetry analysis. In the final part of this work, the Fe@Fe2O3/3D-GO electrode was used as the cathode electrode in the heterogeneous EF process to remove SU from aqueous solutions. The effect of operating parameters such as applied current (mA), initial pH of solution, initial pharmaceutical concentration (mg L-1) and process time (min) on pharmaceutical removal efficiency under heterogeneous EF process was investigated by response surface methodology. The results showed that the optimum values for applied current, pH, initial pharmaceutical concentration and electrolysis time were respectively 300 mA, 7, 30 mg L-1 and 100 min, resulting 99.60% of SU removal. Finally, the intermediates of SU degradation were determined by Gas chromatography-mass spectrometry analysis and the amount of mineralization was determined by total organic carbon analysis. About 5.2% drop in the SU removal efficiency was observed within 8 operational runs. (C) 2020 Elsevier Ltd. All rights reserved.
dc.description.sponsorshipUniversity of Tabriz (Iran)
dc.description.sponsorshipUniversity of Tabriz [825, 1397.3.5]
dc.description.sponsorshipThe authors thank the University of Tabriz (Iran) for all supports provided. The project is supported by a research grant of University of Tabriz (Project No: 825, 1397.3.5).
dc.identifier.doi10.1016/j.chemosphere.2020.128581
dc.identifier.issn0045-6535
dc.identifier.issn1879-1298
dc.identifier.orcid0000-0003-2554-3848
dc.identifier.pmid33082000
dc.identifier.scopus2-s2.0-85092655451
dc.identifier.scopusqualityQ1
dc.identifier.urihttps://doi.org/10.1016/j.chemosphere.2020.128581
dc.identifier.urihttps://hdl.handle.net/20.500.14854/11307
dc.identifier.volume273
dc.identifier.wosWOS:000641584000037
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherPergamon-Elsevier Science Ltd
dc.relation.ispartofChemosphere
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20251020
dc.subjectAdvanced oxidation processes
dc.subjectElectro-fenton process
dc.subjectFe@Fe2O3/3D-GO
dc.subjectResponse surface methodology
dc.subjectSulfasalazine
dc.titlePreparation of Fe@Fe2O3/3D graphene composite cathode for electrochemical removal of sulfasalazine
dc.typeArticle

Dosyalar