Seismic performance of concentrically braced frames with and without brace buckling

dc.contributor.authorShen, Jay
dc.contributor.authorŞeker, Onur
dc.contributor.authorAkbaş, Bülent
dc.contributor.authorSeker, Pinar
dc.contributor.authorMomenzadeh, Seyedbabak
dc.contributor.authorFaytarouni, Mahmoud
dc.date.accessioned2025-10-29T11:27:56Z
dc.date.issued2017
dc.departmentFakülteler, Mühendislik Fakültesi, İnşaat Bölümü
dc.description.abstractThis paper presents an analytical study on seismic performance of special concentrically braced frames (SCBFs) with and without brace buckling. It demonstrates that the collapse prevention goal needs attention in modern buildings using SCBFs as main seismic-force-resisting systems, and an simple and low-cost solution is possible to achieve this goal. Typical 6-story buildings using two-story X-braced frames with strong and weak braced-intersected beams and inverted V braced frames with and without brace buckling were subjected to a set of 15 earthquake ground motions, and resulting seismic responses were discussed in terms of seismic strength and deformation demands on braces, beams and columns. The study finds that the braces in SCBFs often fracture prior to 2% story drift ratio response, particularly in the popular two-story X-braced frames with weak beams, mainly due to premature yielding of the beams. The buckling-controlled braced frames (BCBFs) are shown to be a cost-effective system to improve the seismic performance of SCBFs. The analysis indicates that the buckling-controlled braces may substantially reduce story drift response, eliminate weak beam yielding, and prevent braces from fracturing. (C) 2017 Elsevier Ltd. All rights reserved.
dc.description.sponsorshipAmerican Institute of Steel Construction (AISC)
dc.description.sponsorshipThe paper was made possible by the support of American Institute of Steel Construction (AISC). The opinions expressed in this paper are those of the authors and do not necessarily reflect the views of AISC.
dc.identifier.doi10.1016/j.engstruct.2017.03.043
dc.identifier.endpage481
dc.identifier.issn0141-0296
dc.identifier.issn1873-7323
dc.identifier.orcid0000-0002-5463-7977
dc.identifier.scopus2-s2.0-85016456320
dc.identifier.scopusqualityQ1
dc.identifier.startpage461
dc.identifier.urihttps://doi.org/10.1016/j.engstruct.2017.03.043
dc.identifier.urihttps://hdl.handle.net/20.500.14854/10959
dc.identifier.volume141
dc.identifier.wosWOS:000400879700033
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherElsevier Sci Ltd
dc.relation.ispartofEngineering Structures
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20251020
dc.subjectBuckling-controlled brace
dc.subjectBrace fracture
dc.subjectBrace-intersected beam
dc.subjectTwo-story X-braced CBF
dc.subjectDuctility
dc.titleSeismic performance of concentrically braced frames with and without brace buckling
dc.typeArticle

Dosyalar