A glucose biosensor based on novel Lutetium bis-phthalocyanine incorporated silica-polyaniline conducting nanobeads

dc.contributor.authorAl-Sagur, H.
dc.contributor.authorKomathi, S.
dc.contributor.authorKarakas, H.
dc.contributor.authorAtilla, D.
dc.contributor.authorGurek, A. G.
dc.contributor.authorBasova, T.
dc.contributor.authorFarmilo, N.
dc.date.accessioned2025-10-29T11:30:14Z
dc.date.issued2018
dc.departmentFakülteler, Temel Bilimler Fakültesi, Kimya Bölümü
dc.description.abstractThe facile preparation of highly sensitive electrochemical bioprobe based on lutetium phthalocyanine incorporated silica nanoparticles (SiO2(LuPc2)) grafted with Poly(vinyl alcohol-vinyl acetate) itaconic acid (PANI (PVIA)) doped polyaniline conducting nanobeads (SiO2(LuPc2)PANI(PVIA)-CNB) is reported. The preparation of CNB involves two stages (i) pristine synthesis of LuPc2 incorporated SiO2 and PANI(PVIA); (ii) covalent grafting of PANI(PVIA) onto the surface of SiO2(LuPc2). The morphology and other physico-chemical characteristics of CNB were investigated. The scanning electron microscopy images show that the average particle size of SiO2(LuPc2)PANI(PVIA)-CNB was between 180-220 nm. The amperometric measurements showed that the fabricated SiO2(LuPc2)PANI(PVIA)-CNB/GOx biosensor exhibited wide linear range (1-16 mM) detection of glucose with a low detection limit of 0.1 mM. SiO2(LuPc2)PANI(PVIA)-CNB/GOx biosensor exhibited high sensitivity (38.53 mu A mM(-1) cm(-2)) towards the detection of glucose under optimized conditions. Besides, the real (juice and serum) sample analysis based on a standard addition method and direct detection method showed high precision for measuring glucose at SiO2(LuPc2)PANI(PVIA)-CNB/GOx biosensor. The SiO2(LuPc2)PANI (PVIA)-CNB/GOx biosensor stored under refrigerated condition over a period of 45 days retains similar to 96.4% glucose response current.
dc.description.sponsorshipMinistry of Higher Education and Scientific Research (MOHESR)
dc.description.sponsorshipCollege of Medicine/Thi Qar University in the south of Iraq
dc.description.sponsorshipGebze Technical University [2017-A-101-01]
dc.description.sponsorshipNikolaev Institute of Inorganic Chemistry, Russia [V.44.4.3]
dc.description.sponsorshipHadi Al-Sagur acknowledges the financial support provided for his PhD study from the Ministry of Higher Education and Scientific Research (MOHESR) and the College of Medicine/Thi Qar University in the south of Iraq. H. Karakas, D. Atilla, A. G. Gurek acknowledge the research fund by Gebze Technical University (Project No.: 2017-A-101-01). T. Basova acknowledges the research fund by Nikolaev Institute of Inorganic Chemistry, Russia (basic project, V.44.4.3).
dc.identifier.doi10.1016/j.bios.2017.12.004
dc.identifier.endpage645
dc.identifier.issn0956-5663
dc.identifier.issn1873-4235
dc.identifier.orcid0000-0003-1263-1005
dc.identifier.orcid0000-0002-4261-5965
dc.identifier.pmid29253816
dc.identifier.scopus2-s2.0-85037973365
dc.identifier.scopusqualityQ1
dc.identifier.startpage637
dc.identifier.urihttps://doi.org/10.1016/j.bios.2017.12.004
dc.identifier.urihttps://hdl.handle.net/20.500.14854/11468
dc.identifier.volume102
dc.identifier.wosWOS:000424176600084
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherElsevier Advanced Technology
dc.relation.ispartofBiosensors & Bioelectronics
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20251020
dc.subjectSilica nanoparticles
dc.subjectConducting nanobeads
dc.subjectLutetium phthalocyanine
dc.subjectGlucose biosensor
dc.subjectPANI(PVIA)
dc.titleA glucose biosensor based on novel Lutetium bis-phthalocyanine incorporated silica-polyaniline conducting nanobeads
dc.typeArticle

Dosyalar