Cyclic failure analysis of the beam-to-column dowel connections in precast industrial buildings

dc.contributor.authorZoubek, Blaz
dc.contributor.authorIsakovic, Tatjana
dc.contributor.authorFahjan, Yasin
dc.contributor.authorFischinger, Matej
dc.date.accessioned2025-10-29T11:27:56Z
dc.date.issued2013
dc.departmentGebze Teknik Üniversitesi
dc.description.abstractThe dowel type of the connection is the most common in Europe. However, the knowledge about its seismic behaviour was incomplete and poorly understood. To analyse the failure of dowel mechanism the numerical model in the FEA software ABAQUS was defined and calibrated using the results of the experimental investigations. Cyclic as well as monotonic response was analyzed. The most important observations are: (1) standard theory assuming that the failure mechanism is initiated by flexural yielding of the dowel and crushing of the surrounding concrete has been confirmed, (2) the strength of the connection considerably depends on the depth of the plastic hinge in the dowel, (3) in the case of the cyclic loading the strength is reduced due to the smaller depth of the plastic hinge, (4) neoprene bearing pad can considerably increase the strength of the connection, particularly when large relative displacements between the beam and the column are developed, and (5) in the case of large rotations between the beam and the column, cyclic resistance is reduced by 15-20%, because the dowel is loaded not only in flexure but also in tension. (C) 2013 Elsevier Ltd. All rights reserved.
dc.description.sponsorshipEuropean Commission [218417-2]
dc.description.sponsorshipThe presented research was supported by the SAFECAST Project Performance of Innovative Mechanical Connections in Precast Building Structures under Seismic Conditions (Grant Agreement No. 218417-2) in the framework of the Seventh Framework Programme (FP7) of the European Commission. Experiments were completed at the Slovenian National Building and Civil Engineering Institute (ZAG). The specimens were constructed at Primorje d.d. company.
dc.identifier.doi10.1016/j.engstruct.2013.02.028
dc.identifier.endpage191
dc.identifier.issn0141-0296
dc.identifier.orcid0000-0003-1254-4526
dc.identifier.scopus2-s2.0-84875769038
dc.identifier.scopusqualityQ1
dc.identifier.startpage179
dc.identifier.urihttps://doi.org/10.1016/j.engstruct.2013.02.028
dc.identifier.urihttps://hdl.handle.net/20.500.14854/10963
dc.identifier.volume52
dc.identifier.wosWOS:000319951400017
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherElsevier Sci Ltd
dc.relation.ispartofEngineering Structures
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20251020
dc.subjectDowel connection
dc.subjectPrecast industrial buildings
dc.subjectSeismic response
dc.subjectFailure mechanism
dc.subjectFailure analysis
dc.titleCyclic failure analysis of the beam-to-column dowel connections in precast industrial buildings