The quartz crystal microbalance (QCM) was used to investigate the liquid sensing properties of a set of phthalocyanines (Pcs) which were systematically varied by attaching the substituent 2,2,3,3-tetrafluoropropyloxy to different positions and by introducing a central metal ion (i.e. Ni(2+), Zn(2+), and Cu(2+)). The responses to low concentrations of organic compounds such as hydrocarbons and chlorocarbons dissolved in water were recorded. The materials were very sensitive to the tested compounds with detection limits in the lower parts-per-million range and they exhibited a good sensing performance as the sensors have been working fully reversibly and reliably over long periods of time. Besides, the influence of substitution pattern and choice of central metal ion on the liquid sensing properties of Pcs were studied for the first time. The results show that the responses differ notably from each other depending on the modifications made to the Pc. Finally, it is demonstrated that the gas and liquid sensing responses of the materials are highly correlated and can be linked to each other with the help of a basic physical model. (C) 2010 Elsevier B.V. All rights reserved.

Açıklama

Anahtar Kelimeler

Chemical sensor, Quartz crystal microbalance, Liquid sensing, Phthalocyanine, Organic pollutant, Response modeling

Kaynak

Sensors and Actuators B-Chemical

WoS Q Değeri

Scopus Q Değeri

Cilt

155

Sayı

1

Künye

Onay

İnceleme

Ekleyen

Referans Veren