Experimental and numerical study on vibration mitigation of slender structures with TLCD under second-order effects

dc.contributor.authorNavdar, Muhammet Burhan
dc.contributor.authorCelebi, Erkan
dc.contributor.authorEngin, Tahsin
dc.contributor.authorDal, Huseyin
dc.contributor.authorYilmaz, Firat Can
dc.date.accessioned2025-10-29T11:26:17Z
dc.date.issued2025
dc.departmentGebze Teknik Üniversitesi
dc.description.abstractThis study experimentally and numerically investigates the importance and methodology of designing a Tuned Liquid Column Damper (TLCD) system for a slender single-degree-of-freedom (SDOF) structure under second-order (P- ) effects. The dynamic characteristics of slender structures under P- effects were experimentally tested and numerically validated with respect to the drift sensitivity coefficient (theta). Then, the optimum liquid column length of TLCD was calculated using experimental and numerical techniques. The study evaluated the performance of TLCDs designed with and without consideration of P- effects based on structural responses in the frequency and time domains under free vibration, swept sine excitation, and seismic loads. Numerical models of the TLCD, the uncontrolled and the controlled structures were developed using individually obtained constitutive parameters and validated with State Space models for nonlinear and equivalent linear systems. Experimental results indicated that the TLCD system tuned with consideration of P- effects exhibit significantly improved performance compared to the system designed without such consideration, showing average vibration mitigation ratios (VMRPEAK) of 43.5% for swept-sine excitation and 30.5% for seismic loads in terms of maximum acceleration and displacement. The vibration mitigation ratios for RMS (VMRRMS) acceleration and displacement values were, on average, 32.5 % across seismic loads. In addition, parametric analyses highlighted that TLCD systems neglecting P- effects deviated from optimal configurations as theta increases, resulting in a notable decline in vibration mitigation performance. In conclusion, P- effects substantially influence the dynamic properties of structures, making their consideration essential for the effective design of TLCD systems.
dc.description.sponsorshipScientific and Technological Research Council of Turkiye (TUBITAK) [221M148]
dc.description.sponsorshipSakarya University, Turkiye
dc.description.sponsorshipThis research was funded by the Scientific and Technological Research Council of Turkiye (TUBITAK), grant number 221M148 and The APC was funded by Sakarya University, Turkiye
dc.identifier.doi10.1016/j.jobe.2024.111675
dc.identifier.issn2352-7102
dc.identifier.orcid0000-0002-9069-5816
dc.identifier.scopus2-s2.0-85216640458
dc.identifier.scopusqualityQ1
dc.identifier.urihttps://doi.org/10.1016/j.jobe.2024.111675
dc.identifier.urihttps://hdl.handle.net/20.500.14854/10210
dc.identifier.volume102
dc.identifier.wosWOS:001422669400001
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherElsevier
dc.relation.ispartofJournal of Building Engineering
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20251020
dc.subjectExperimental investigation
dc.subjectPassive vibration mitigation
dc.subjectParameter optimization
dc.subjectSecond order effect
dc.titleExperimental and numerical study on vibration mitigation of slender structures with TLCD under second-order effects
dc.typeArticle

Dosyalar