Ferromagnetic resonance study of iron implanted PET foils

dc.contributor.authorOkay, C
dc.contributor.authorRameev, BZ
dc.contributor.authorKhaibullin, RI
dc.contributor.authorOkutan, M
dc.contributor.authorYildiz, F
dc.contributor.authorPopok, VN
dc.contributor.authorAktas, B
dc.date.accessioned2025-10-29T11:33:48Z
dc.date.issued2006
dc.departmentFakülteler, Temel Bilimler Fakültesi, Fizik Bölümü
dc.descriptionInternational Conference on Nanoscale Magnetism (ICNM 2005) -- JUL 03-07, 2005 -- Gebze, TURKEY
dc.description.abstractPolyethylene terephthalate (PET) foils were implanted with 40 keV Fe+ ions to doses of (0.15-1.50) x 10(17) ions/cm(2) at ion current density of 4 mu A/cm(2). The iron-implanted PET composites were investigated using ferromagnetic resonance (FMR) technique supplemented by transmission electron microscopy (TEM), atomic force microscopy (AFM) and DC resistance measurements. TEM studies revealed formation of iron nanoparticles with size in the range of 5-100 run depending on the implantation dose. AFM images showed depending on the implantation dose either small bumps or worm-like structures on the polymer surface that corresponded to the inclusions towered above the surface. The results of AFM studies were found to be in good agreement with the TEM measurements. FMR signal was observed for the foils implanted with the dose higher than 0.15 x 10(17) ions/cm(2). The effective magnetization of the metal-polymer composite was extracted from the angular dependencies of FMR resonance field. The percolation transition at the implantation dose of 1.0 x 10(17) ions/cm(2) was observed in the dose dependencies of the FMR absorption intensity and the effective magnetisation. The minimum in DC resistance found at the same dose indicates that a charge carrier mediated (exchange) interaction rather than the dipolar one is underlying mechanism for the percolation transition. Formation of a carbonized layer in the heavily implanted area of the polymer is supposed to be responsible for the exchange coupling of the magnetic granules. (c) 2006 WILEY-VCH Verlag GmbH & Co. KGa.A, Weinheim.
dc.identifier.doi10.1002/pssa.200563118
dc.identifier.endpage1532
dc.identifier.issn0031-8965
dc.identifier.issue7
dc.identifier.orcid0000-0002-2335-6734
dc.identifier.orcid0000-0003-0828-8312
dc.identifier.orcid0000-0002-5707-8090
dc.identifier.orcid0000-0002-9480-3765
dc.identifier.scopus2-s2.0-33745069039
dc.identifier.scopusqualityN/A
dc.identifier.startpage1525
dc.identifier.urihttps://doi.org/10.1002/pssa.200563118
dc.identifier.urihttps://hdl.handle.net/20.500.14854/12583
dc.identifier.volume203
dc.identifier.wosWOS:000238034600005
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherWiley-V C H Verlag Gmbh
dc.relation.ispartofPhysica Status Solidi A-Applications and Materials Science
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20251020
dc.subjectThin-Films
dc.titleFerromagnetic resonance study of iron implanted PET foils
dc.typeConference Object

Dosyalar