An occlusion insensitive adaptive focus measurement method
| dc.contributor.author | Aydin, Tarkan | |
| dc.contributor.author | Akgul, Yusuf Sinan | |
| dc.date.accessioned | 2025-10-29T11:12:26Z | |
| dc.date.issued | 2010 | |
| dc.department | Gebze Teknik Üniversitesi | |
| dc.description.abstract | This paper proposes a new focus measurement method for Depth From Focus to recover depth of scenes. The method employs an all-focused image of the scene to address the focus measure ambiguity problem of the existing focus measures in the presence of occlusions. Depth discontinuities are handled effectively by using adaptively shaped and weighted support windows. The size of the support window can be increased conveniently for more robust depth estimation without introducing any window size related Depth From Focus problems. The experiments on the real and synthetically refocused images show that the introduced focus measurement method works effectively and efficiently in real world applications. (C) 2010 Optical Society of America | |
| dc.description.sponsorship | TUBITAK [105E097] | |
| dc.description.sponsorship | This work was conducted at the Computer Vision Laboratory at Gebze Institute of Technology. It was supported by TUBITAK Career Project 105E097. | |
| dc.identifier.doi | 10.1364/OE.18.014212 | |
| dc.identifier.endpage | 14224 | |
| dc.identifier.issn | 1094-4087 | |
| dc.identifier.issue | 13 | |
| dc.identifier.orcid | 0000-0002-2018-405X | |
| dc.identifier.orcid | 0000-0001-8501-4812 | |
| dc.identifier.pmid | 20588555 | |
| dc.identifier.scopus | 2-s2.0-77953868089 | |
| dc.identifier.scopusquality | Q1 | |
| dc.identifier.startpage | 14212 | |
| dc.identifier.uri | https://doi.org/10.1364/OE.18.014212 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14854/6276 | |
| dc.identifier.volume | 18 | |
| dc.identifier.wos | WOS:000279009900096 | |
| dc.identifier.wosquality | Q1 | |
| dc.indekslendigikaynak | Web of Science | |
| dc.indekslendigikaynak | Scopus | |
| dc.indekslendigikaynak | PubMed | |
| dc.language.iso | en | |
| dc.publisher | Optical Soc Amer | |
| dc.relation.ispartof | Optics Express | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.snmz | KA_WOS_20251020 | |
| dc.subject | Depth | |
| dc.subject | Defocus | |
| dc.subject | Shape | |
| dc.subject | Recovery | |
| dc.subject | Stereo | |
| dc.title | An occlusion insensitive adaptive focus measurement method | |
| dc.type | Article |








