Mitigation of high-speed train induced surface vibrations by open trench with aerated concrete panel walls
Yükleniyor...
Tarih
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Elsevier Sci Ltd
Erişim Hakkı
info:eu-repo/semantics/closedAccess
Özet
The aim of this study is to examine the vibration behavior of a special test building close to the high-speed railway line. The surface wave propagation in the most unfavorable geotechnical conditions produced by the moving load source under passively isolated and non-isolated site conditions. For this purpose, special prefabricated panels with low impedance were used to be placed in the trench. Isolation effectiveness of open trench with thin aerated concrete walls is studied on structural response and free-field surface ground vibrations. An important isolation performance of up to 12 dB was obtained only at the half-wavelength depth of excavation.
Açıklama
Anahtar Kelimeler
High-speed train, In-situ measurement, Free field environmental surface vibration, Test building response, Passive isolation, Open trench with aerated concrete wall, Alluvial soil deposit, Velocity level in DB
Kaynak
Construction and Building Materials
WoS Q Değeri
Scopus Q Değeri
Cilt
400