Pre-focused lead titanate >25 MHz single-element transducers from hollow spheres
| dc.contributor.author | Meyer, Richard J. | |
| dc.contributor.author | Newnham, Robert E. | |
| dc.contributor.author | Alkoy, Sedat | |
| dc.contributor.author | Ritter, Timothy A. | |
| dc.contributor.author | Cochran, Joseph K. | |
| dc.date.accessioned | 2025-10-29T12:08:09Z | |
| dc.date.issued | 2001 | |
| dc.department | Fakülteler, Mühendislik Fakültesi, Malzeme Bilimi ve Mühendisliği Bölümü | |
| dc.description.abstract | Miniature lead titanate (PT) hollow spheres with diameter in the 1 to 10 mm range and wall thicknesses of 20 to 120 ?m have been fabricated. Shell sections were used as components of pre-focused transducers. Spheres are produced using a new sacrificial core technique that produces hundreds of spheres with a more uniform wall thickness than those produced by earlier methods. Shells produced from these spheres were found to have a wall thickness variation of about 10%. Despite this variation, bulk properties were estimated from capacitance and impedance data. Shells tested in this work had dielectric constants (1 kHz) near 280 with loss factor of <2% and d<inf>33</inf> values of 68 pC/N. Thickness coupling coefficients averaged 0.51 with mechanical quality factors of <15. A transducer fabricated from these sections of spheres had a round-trip insertion loss of -20.1 dB at the center frequency of 39.8 MHz and a 6 dB bandwidth of 33%. © 2008 Elsevier B.V., All rights reserved. | |
| dc.identifier.doi | 10.1109/58.911731 | |
| dc.identifier.endpage | 493 | |
| dc.identifier.issn | 0885-3010 | |
| dc.identifier.issn | 1525-8955 | |
| dc.identifier.issue | 2 | |
| dc.identifier.pmid | 11370362 | |
| dc.identifier.scopus | 2-s2.0-0035273076 | |
| dc.identifier.scopusquality | Q1 | |
| dc.identifier.startpage | 488 | |
| dc.identifier.uri | https://doi.org/10.1109/58.911731 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14854/14311 | |
| dc.identifier.volume | 48 | |
| dc.indekslendigikaynak | Scopus | |
| dc.indekslendigikaynak | PubMed | |
| dc.language.iso | en | |
| dc.relation.ispartof | IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.snmz | KA_Scopus_20251020 | |
| dc.subject | Bandwidth | |
| dc.subject | Capacitance | |
| dc.subject | Electric impedance | |
| dc.subject | Electric losses | |
| dc.subject | Permittivity | |
| dc.subject | Spheres | |
| dc.subject | Hollow spheres | |
| dc.subject | Single-element transducers | |
| dc.subject | Transducers | |
| dc.subject | lead | |
| dc.subject | titanium | |
| dc.subject | article | |
| dc.subject | biomedical engineering | |
| dc.subject | echography | |
| dc.subject | equipment design | |
| dc.subject | human | |
| dc.subject | instrumentation | |
| dc.subject | scanning electron microscopy | |
| dc.subject | transducer | |
| dc.subject | Biomedical Engineering | |
| dc.subject | Equipment Design | |
| dc.subject | Humans | |
| dc.subject | Lead | |
| dc.subject | Microscopy, Electron, Scanning | |
| dc.subject | Titanium | |
| dc.subject | Ultrasonography | |
| dc.title | Pre-focused lead titanate >25 MHz single-element transducers from hollow spheres | |
| dc.type | Article |








