Flow injection determination of catechol based on polypyrrole-carbon nanotube-tyrosinase biocomposite detector

dc.contributor.authorOzoner, Seyda Korkut
dc.contributor.authorYalvac, Mevra
dc.contributor.authorErhan, Elif
dc.date.accessioned2025-10-29T11:30:06Z
dc.date.issued2010
dc.departmentFakülteler, Mühendislik Fakültesi, Çevre Mühendisliği Bölümü
dc.description.abstractA flow injection catechol biosensor based on tyrosinase entrapped in carbon nanotube modified polypyrrole biocomposite film on a glassy carbon surface has been developed. Amperometric response was measured as a function of concentration of catechol, at a fixed bias voltage of -50 mV at a flow rate of 1 mL/min. The proposed biosensor exhibited impressive analytical performance such as a linear range between 3 and 50 mu M, a short response time (10 s), a detection limit of 0.671 mu M and an excellent operational (with a relative standard deviation of 0.54%) and long-term stability (85% remained after 10th week). A comparison of the analytical parameters of the developed biosensor with polypyrrole/tyrosinase film electrode was performed in the study. CNT was shown to enhance the electron transfer between the electrode and enzyme and capable to carry higher bioactivity owing to its intensified surface area. (C) 2009 Elsevier B.V. All rights reserved.
dc.description.sponsorshipThe Scientific & Technological Research Council of Turkey (TUBITAK) [105Y130]
dc.description.sponsorshipThe authors are grateful to The Scientific & Technological Research Council of Turkey (TUBITAK) for financial support of this project under Grant No. 105Y130.
dc.identifier.doi10.1016/j.cap.2009.06.017
dc.identifier.endpage328
dc.identifier.issn1567-1739
dc.identifier.issn1878-1675
dc.identifier.issue1
dc.identifier.orcid0000-0003-2892-6182
dc.identifier.scopus2-s2.0-69249206612
dc.identifier.scopusqualityQ2
dc.identifier.startpage323
dc.identifier.urihttps://doi.org/10.1016/j.cap.2009.06.017
dc.identifier.urihttps://hdl.handle.net/20.500.14854/11426
dc.identifier.volume10
dc.identifier.wosWOS:000270584900061
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherElsevier
dc.relation.ispartofCurrent Applied Physics
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20251020
dc.subjectFlow injection
dc.subjectBiosensor
dc.subjectPolypyrrole
dc.subjectCarbon nanotube
dc.subjectCatechol
dc.subjectTyrosinase
dc.titleFlow injection determination of catechol based on polypyrrole-carbon nanotube-tyrosinase biocomposite detector