Effect of excessive fiber reinforcement on mechanical properties of chopped glass fiber reinforced polymer concretes

dc.contributor.authorUlu, Arif
dc.contributor.authorTutar, Ali Ikbal
dc.contributor.authorKurklu, Ahmet
dc.contributor.authorÇakır, Ferit
dc.date.accessioned2025-10-29T11:29:36Z
dc.date.issued2022
dc.departmentFakülteler, Mühendislik Fakültesi, İnşaat Bölümü
dc.description.abstractPolymer concretes (PCs) have evolved with the growing need for special concretes in the construction sector such as swimming pools, sewer structures, drainage channels, reinforcement injection, and other structures that contain liquids or corrosive chemicals. Recently, these concretes have been prioritized and their importance is growing. In this study, chopped glass fiber (CGF) reinforced polymer concretes (CGFRPCs) are emphasized and the effect of excessive fiber reinforcement on the mechanical properties of concrete is investigated. In this regard, six different mixtures; M1 (Pure PC), M2 (0.15 % CGFs), M3 (0.20 % CGFs), M4 (0.25 % CGFs), M5 (0.50 % CGFs), M6 (1.0 % CGFs); were prepared by considering 0, 0.6, 0.8, 1, 2 and 4 reinforcing indexes (RIs) with a constant aspect ratio (6/0.015 = 400), respectively. Then, the initial setting time, final setting time, peak temperature and flow tests are performed on the fresh concrete samples. The density, flexural strength and compressive strength at 7, 14, 21 and 28 days are determined on the prism and cube samples as the hardened concrete tests. Besides, scanning electron microscope (SEM) examinations are performed to obtain detailed in-formation about the behavior of the concretes. The experimental studies and SEM evaluations show that excessive fiber reinforcement negatively affects both fresh concrete properties and hardened concrete properties because of fiber agglomeration, thixotropy, fiber pull-out, fiber breakage, dislodged aggregate, interface and matrix cracks. In addition, it is observed that the problems observed in the CFRPCs increase as the RI increases.
dc.description.sponsorshipMert Casting Co
dc.description.sponsorshipGebze Technical University
dc.description.sponsorship[Ar-Ge-M11]
dc.description.sponsorship[TTO-AR-GE 21]
dc.description.sponsorship[077843]
dc.description.sponsorshipFunding This work was supported by Mert Casting Co (Project No: Ar-Ge-M11) and Gebze Technical University (Project No: TTO-AR-GE 21;STB Project Code: 077843) in Turkey.
dc.identifier.doi10.1016/j.conbuildmat.2022.129486
dc.identifier.issn0950-0618
dc.identifier.issn1879-0526
dc.identifier.orcid0000-0003-2577-075X
dc.identifier.scopus2-s2.0-85140487381
dc.identifier.scopusqualityQ1
dc.identifier.urihttps://doi.org/10.1016/j.conbuildmat.2022.129486
dc.identifier.urihttps://hdl.handle.net/20.500.14854/11169
dc.identifier.volume359
dc.identifier.wosWOS:000882204800002
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherElsevier Sci Ltd
dc.relation.ispartofConstruction and Building Materials
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20251020
dc.subjectChopped Glass Fiber
dc.subjectPolymer Concrete
dc.subjectReinforcing Index
dc.subjectExcessive Fiber Reinforcement
dc.subjectFiber Agglomeration
dc.subjectFresh Concrete Tests
dc.subjectHardened Concrete Tests
dc.titleEffect of excessive fiber reinforcement on mechanical properties of chopped glass fiber reinforced polymer concretes
dc.typeArticle

Dosyalar