Characteristics of silver-containing titanium- based coating after thermal oxidation

Yükleniyor...
Küçük Resim

Tarih

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Emerald Group Publishing Ltd

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

This study has been initiated to form a silver (Ag)-incorporated titanium oxide (TiO2) outermost layer over a medical grade 316L stainless steel by subsequent applications of cold spray (CS) and thermal oxidation (TO) processes. X-ray diffraction analysis, scanning electron microscopy examination and Raman analysis revealed that TO at 600 degrees C for 60 h in the air formed a 3 mm thick exterior layer composed of the rutile form of titanium oxide and metallic silver over the CS coating fabricated by depositing a mixture of 87 wt.% titanium (Ti), 8 wt.% aluminium (Al) and 5 wt.% silver powder. This exterior layer exhibited superior bioactivity and wear resistance along with a sufficient antibacterial activity, which can further be improved by adjusting the distribution and/or content of silver in its structure.

Açıklama

Anahtar Kelimeler

anti-bacterial, coatings, surface characterisation